6 - Tighten the cable gland (F).
7 - Replace the lid (E) and retighten the screws.

CONVERSION OF GAS SUPPLY

The constructor has tested the appliance with its
own mains gas, identified by the sticker applied to
the nameplate.
If the type of gas to be connected is different from
that used for testing, proceed as follows.
1 - Turn off the gas supply tap (A).
2 - Change the burner nozzle (see page 28)
3 - Adjust the gas solenoid valve (see page 26)
4 - Remove the sticker from the nameplate and ap-
ply the new one to identify the gas being used.
Important
On completion of the operation, make sure
that there are no gas leaks or malfunctions.