The appliance has been tested before being
put into service. The information provided
below is intended to assist in the identifi cation
and correction of any anomalies and malfun-
ctions which might occur during use.
The user can solve some of these problems
himself, but for others specifi c technical
knowledge or skill is required, and so they
must only be carried out by qualifi ed staff with
recognised experience acquired in the specifi c
sector of operation.
Faults
The plates do not turn on.
The plates do not turn off .
GB
The heating elements do
not come on.
The appliance does not
heat up to the set tempe-
rature.
3320030_ut_GB_rev.1
FAULT
TROUBLESHOOTING
For all requirements contact the agents or
the headquarters of Angelo Po which can be
found in the contacts section of the website
http://www.angelopo.com.
Causes
Electrical connection not
made correctly.
Safety thermostat tripped.
Switch faulty.
Component fault.
Electrical connection not
made correctly.
Safety thermostat tripped.
Switch faulty.
Thermostat faulty.
- 14 -
Important
Remedies
Check the connection of the
electrical wires.
Contact the after-sales service.
Wait for the thermostat to
automatically reset appliance
operation
(this takes around 30 minutes).
Contact the after-sales service.
Replace the switch.
Contact the after-sales service.
Contact the after-sales service.
Check the connection of the
electrical wires.
Contact the after-sales service.
Carry out the appliance reset.
Contact the after-sales service.
Replace the switch.
Contact the after-sales service.
Replace the thermostat.
Contact the after-sales service.
ENGLISH