7.4
Faults
7.4.1
Faults without fault number
Description
possible cause
Faulty or no
Measuring instrument
measurement
dirty
Glass plate damaged
Glass plate fogged or
dirty
Malfunction of the
lighting (lighting does
not flash 30 seconds
after it has been
switched on)
Results of
Crossing too fast
measurement are not
displayed
7.4.2
Overview of fault numbers
i
For all other failure indications: contact customer
service.
Fault
Meaning
number
1000
Faulty crossing.
1001
The vehicle was driving too slow.
1002
The vehicle was driving too fast.
1010
Crossing took place too far on the left.
1011
Crossing took place too far on the right.
1012
The track width is too small.
1013
The track width is too large.
1014
No valid vehicle.
1015
Wrong direction of travel.
1016
The tire is too narrow or did not pass over the
measurement window with its entire width.
1017
The tire is too wide.
1100
Not enough measurement results.
1101
No measurement results.
2006
Communication with the remote module not possible.
2008
It is not permitted to switch the operation mode.
2110
The device is in ERROR mode. It cannot be measured.
2111
The device is in READY/UPDATE mode. It cannot be
measured.
2116
Master and Satellite cannot have the same IP address.
2117
This IP address cannot be changed as long as the other
address is not left blank.
2118
Invalid IP address.
2121
Setting of illuminance failed.
Robert Bosch GmbH
Maintenance | TTM 2104 / TTM 2204 | 47 | en
Check
Check measuring instrument for
cleanness.
Visual inspection
Visual inspection
Have all plugs been plugged up
correctly?
Are the M12 plugs of the voltage
supply tightly screwed into the
measuring units?
Are the M12 plug contacts bent?
Cross the device more slowly.
Measures
Repeat crossing
Repeat crossing; drive faster
Repeat crossing; drive slower
Repeat crossing; drive in the center
Repeat crossing; drive in the center
Vehicle cannot be measured
Vehicle cannot be measured
Repeat crossing
Repeat crossing in the other direction
TTire cannot be measured Drive across once more, keep to
center
Tire cannot be measured
Repeat crossing
Repeat crossing
Check wiring and network connection
Information only
Information only
Information only
Correct entry
Correct entry
Correct entry
Restart measuring units; call customer service if fault persists
Measure
Clean the measuring instrument, repeat the
measurement
Contact customer service, if still no or faulty
measurement is possible after the instrument
has been cleaned.
Switch off the measuring unit and contact
Bosch Customer Service.
If the lighting does not flash: clean glass plate,
check again
Contact customer service if the lighting does
not flash even after the glass plate has been
cleaned.
Disconnect measuring units from the power
supply
Wait 10 seconds.
Re-connect power supply of both measuring
units simultaneously.
Wait 30 seconds.
Contact customer service if the lighting still
does not flash following the inspection.
Contact customer service if the measurement
results are still not displayed after crossing
the device again.
1 691 206 005
|