48 | TTM 2104 / TTM 2204 | Maintenance
2122
Master and Satellite have different versions.
2123
Invalid password.
3000
CPU temperature too high.
3001
CPU temperature too low.
3002
The illumination has switched itself off due to an object
permanently present over the measurement window or is
defective.
3003
No network connection between Master and Satellite.
3006
The battery for the RTC component is discharged.
3010
Moisture is higher than usual.
5000
Poor display quality.
5001
The surroundings are too bright.
5002
The measurement window is too dirty.
5003
Too much scattered light.
20480
An error occurred.
20481
Missing or invalid response from measurement system.
20482
Update installation failed.
20483
No measurement data available.
20484
The device is not ready for operation. Please restart the
measuring units.
7.4.3
Charging the battery
1. Connect the module master and satellite to the
power supply.
2. Wait for 30 to 60 minutes.
3. Switch off the TTM 2104 / TTM 2204 .
4. Switch on the TTM 2104 / TTM 2204 .
i
See section 8.2 Settings for steps 5–7:
$
General information
$
Device
5. Enter password.
6. Apply the browser's system date and time.
7. Apply the browser's time zone.
"
"Apply".
i
The device must be connected for approx. 12 hours
for a full battery charge.
|
1 691 206 005
2019-02-25
Match software versions of Master and Satellite
Use the right password
Inappropriate test conditions; switch set-up location
Inappropriate test conditions; switch set-up location
Remove object from measurement window;
Restart measuring units; call customer service if fault persists
Check wiring and network connection
Connect module to electricity,
see chap. 7.4.3
Inappropriate test conditions; switch set-up location
Repeat crossing
Inappropriate test conditions; switch set-up location
Clean
Inappropriate test conditions; switch set-up location
Re-start measuring units; contact customer service if fault
persists
Re-start measuring units; contact customer service if fault
persists
Re-start measuring units; contact customer service if fault
persists
Re-start measuring units; contact customer service if fault
persists
Re-start measuring units; contact customer service if fault
persists