quickly after donning to maintain maximum suspension. A spray pen
accompanies the Seal-In Liner, small enough to fit in a pocket and/or a
handbag. It can be refilled with the Iceross Clean & Simple lubricant spray.
Warning: Do not apply to the skin. Avoid contact with eyes.
Ingredients: Propanol and water.
J. ICELOCK
The Össur Icelock Expulsion Valves are designed and tested to continually
expel air when loading the prosthesis, thus maintaining hypobaric
suspension.
product number
L-551002
K. ICEROSS
Iceross Distal Cups provide enhanced comfort for conical limbs with poor
soft tissue coverage. They can also be used as a fitting tool in conjunction
with the Iceross Original liners to ensure total contact between the
silicone and residual limb. The DERMOGEL silicone in the Iceross Distal
Cup conforms to the limb, thus minimizing pressure over bony
prominence during gait.
To correctly fit a Distal Cup:
1. Measure the circumference of the residual limb at 4cm from the
distal end (Figure A).
2. Choose the Distal Cup two or three sizes smaller than the
measurement.
3. Roll the Distal Cup directly over the limb (Figure K).
4. When using an Iceross liner in combination with a Distal Cup, the
liner measurement (4cm from the distal end) should be made with
the Distal Cup in place (i.e. OVER the Distal Cup) (Figure L).
5. Choose the correct Iceross liner size based on the measurement
obtained with the Distal Cup in place
L. ICEROSS
Iceross Pads can be used to fill in any problem areas (i.e. voids or scars)
to ensure better fit and to minimize trapped air. Iceross Pads may also be
used to distribute body pressure and to protect the skin. In some cases,
custom-formed pads may be required for irregular shapes or problem
areas. See Össur Prosthetic Product Catalogue for more information.
M. LINER CARE
Proper product care is important. The liner needs to be washed inside and
out every day, following use. Your patient should be instructed to remove
the liner, turn the liner inside out and wash it with Iceross Clean and
Simple soap. The liner can also be machine washed (40°C/Hot) with a
mild detergent. Fabric softeners or bleaches or other products or cleaning
solutions may damage the liner and should not be used. After cleaning,
the patient should rinse the liner thoroughly with water and wipe both
sides dry with a lint-free cloth.
An Iceross liner can be used directly after washing. It does not need to dry
over night. Always return the liner to its normal position with the seal
facing out as soon as possible after cleaning. Ensure the seal is positioned
7
product number
S-610250
EXPULSIONS VALVES
®
description
Expulsion Valve
551
DISTAL CUP
®
PADS
®
description
Lubricant Spray
benefits
Small, cosmetic & easy
installation