9 .3
Display messages
DISPLAY MESSAGE
Error, front cap
Remove cable-tie residues
Error, gate
Close gate
Error, start position
1. Operate bandoleer cutter
2. Open gate
Error, start position
1. Remove cable-tie residues
2. Press Reset button
Error, start position
Close gate
Operating Instructions • AT2000 CPK • 02-2017 • v02 • 106-29004
POSSIBLE CAUSE
• There are residues of cable
ties trapped behind the front
cap.
• The level sensor is busy.
• Drum is not in the correct
position.
• The gate is open.
• The AT2000 CPK is not in
the start position.
SOLUTION
f Clean the front sensor.
f If applicable, carefully remove the cable-tie residues.
f Open the gate and turn the drum to the correct
position.
f Close the gate.
f Push actuator for bandoleer cutter to the left.
f Open the gate.
; Error, start position appears as the next
message on the display.
f If applicable, carefully remove the cable-tie residues.
f Press the Reset button.
; Error, start position appears as the next
message on the display.
f Close the gate.
Troubleshooting
2 5