DISPLAY MESSAGE
Overload
1. Operate bandoleer cutter
2. Open gate
Overload
1. Remove cable-tie residues
2. Press Reset button
Error, tensioning motor
1. Operate bandoleer cutter
2. Open gate
Error, binding force
1. Check binding
2. Confirm with trigger
Time loss
1. Check battery in power pack
2. Press Reset button
Operating Instructions • AT2000 CPK • 02-2017 • v02 • 106-29004
POSSIBLE CAUSE
• The drum is blocked.
• The bandoleer cutter does
not cut off the cable ties.
• The cable tie bandoleer is
pulled in at an angle.
• Drive is jammed or is
defective.
• The speciied binding force
is not achieved.
The message appears only if
à "Check of binding" on
error notiication is activated,
page 14.
• The back-up battery for the
clock in the power pack has
discharged.
SOLUTION
f Push actuator for bandoleer cutter to the left.
f Open the gate.
f Open the two service laps at the gate,
à "Troubleshooting a cable-tie bandoleer
malfunction" on page 28.
; Error, overload appears as the next message on
the display.
f If applicable, carefully remove the cable-tie residues.
f Press the Reset button.
; Error, gate appears as the next message on the
display.
f Close the gate.
f Push actuator for bandoleer cutter to the left.
f Open the gate.
f If applicable, carefully remove the cable-tie residues.
f Press the Reset button.
; Error, gate appears as the next message on the
display.
f Close the gate.
f Check the binding.
f If applicable, reset the binding force.
f If applicable, carefully remove the cable-tie residues.
f Press the trigger as conirmation.
f Change the back-up battery, à "Changing back-up
battery" on page 29.
f Press the Reset button.