Fig. 9: Lifting equipment secured with cable
bollard
6.5

Electrical connection

6.5.1
Line-side fuse protection
Installation and operating instructions Wilo-EMU TR/TRE 212 ... 326-3
Installation and electrical connection
Mobile hoist: Installing a cable bollard
If a mobile hoist is used, install a cable bollard at the edge of the basin:
ƒ
Remove lifting equipment (e.g. wire rope) from the hoist and secure it to the cable bol-
lard.
ƒ
Secure the connection cable at the edge of the basin to prevent it from falling.
CAUTION! If the connection cable leads over the edge of the basin, beware of potential
abrasion. Sharp edges may damage the connection cable. Bevel the basin edge if neces-
sary!
DANGER
Electrocution hazard!
Improper conduct when carrying out electrical work causes death due to electric shock!
Electrical work must be carried out by a qualified electrician in accordance with local reg-
ulations.
DANGER
Risk of explosion due to incorrect connection!
• Always connect the mixer to an electrical outlet outside the explosive area. If the
connection must be made within the explosive area, then the connection must be
carried out in an Ex-rated housing (ignition protection class according to
DIN EN 60079‑0)! Non-observance may lead to a risk of fatal injury due to explo-
sion!
• Connect the potential compensator to the ground terminal indicated. The ground
terminal is installed in the area of the connection cable. A cable cross-section in ac-
cordance with the locally applicable regulations must be used for the potential com-
pensator.
• Connection must always be carried out by a qualified electrician.
• For the electrical connection, also note the additional information in the chapter on
potentially explosive areas found in the appendix of these installation and operating
instructions!
ƒ
The mains connection must match the specifications on the rating plate.
ƒ
Power supply on the mains side for three-phase current motors with clockwise rotating
field.
ƒ
Lay the connection cable in accordance with the locally applicable regulations and con-
nect it according to the wire assignment.
ƒ
Connect monitoring devices and check function.
ƒ
Carry out earthing properly according to the local regulations.
Circuit breaker
The size and switching characteristics of the circuit breakers must conform to the rated cur-
rent of the product connected. Observe the locally applicable regulations.