6.2.7. Mounting the controller mounting plate (only ELS 150-ELS 480 without eDrive)
Figure 7: Controller mounting plate ELS 150 - 480 without eDrive
6.2.8.
Mounting the bracket for TC 304/TC 504 (only ELS 150-ELS 480 without eDrive)
This way up
Figure 8: Mounting the TC 304/TC 504 bracket (ELS 150-ELS 480 without eDrive)
6.2.9.
Mounting the bracket forST 411/ST 630/ST 632 (only ELS 150-ELS 480 without eDrive)
This way up
Figure 9: Mounting the ST 411/ST 630/ST 632 bracket (ELS 150-ELS 480 without eDrive)
Attach the supplied controller mounting plate to the kiln casing on
the left-hand side using the star knob screw provided.
The inclination of the controller mounting plate can be adjusted.
Applies to ELS 150-ELS 480 without eDrive.
The mounting plate can also be positioned on the right side of the
kiln, if the hinge of the kiln door is then attached on the left side.
Controller mounting
plate (see the previous
section)
Control unit bracket
Bracket screw
connections (3x)
Controller mounting
plate (see the previous
section)
Control unit bracket
Bracket screw
connections (2x)
94 / 492 - EN -
Mount the bracket of the TC 304 or TC 504
control unit with the aid of the fastening material
so that the one mounting hole is at the top and
the two holes at the bottom.
The fastening material is included in the scope of
delivery of the control unit.
Applies to ELS 150-ELS 480 without eDrive.
Mount the bracket for the ST 411, ST 630 or
ST 632 control unit using the fastening
material in such a way that the arrow
embossed on the bracket points upwards.
The fastening material is included in the
scope of delivery of the control unit.