4
Setting Up
4.1
Unpacking
EN
⇒ Remove the device and all the accessories from the delivery package�
⇒ Check the delivery for completeness (refer to the "Scope of Delivery" section)�
4.2
Setup
The extraction unit is a free standing appliance which must not be operated in a lying position�
Position the extraction device so that:
• The exhaust air outlet (11, Fig� 1) is not blocked�
• The front of the device is easily accessible for removal of dust drawer�
If the extraction unit is kept in a closed cupboard, the warm exhaust air must be allowed to escape
using one of the methods, shown on the pictures A, B, C at the begining of this document.
• External exhaust air duct (A) (see chapter� 4�6)�
• An opening in the cupboard back side (B) min� 250 x 120 mm, directly opposite the exhaust air
outlet (11, Fig� 1)�
- Distance from the cupboard back side to the wall:
- Distance from the extraction unit to the cupboard back side: max� 25 mm�
• Remove the back side of the cupboard (C), distance from the back of the cupboard to the wall min�
50 mm�
If the warm exhaust air is passed out of the opening vent at the back of the cupboard, ensure that the
warm air can escape without hindrance�
4.3
Electrical Connection
Before connecting the device, ensure that the voltage information on the identification plate corre-
sponds with your local power supply.
Arrange the conducting parts (plug sockets, plugs and couplings) and install the extension cord
so that the protection class is retained.
⇒ Switch the device OFF at the On / Off switch (3, Fig� 2)�
⇒ Insert the mains cable (9, Fig� 1) into the building installed wall socket�
4.4
Connection to the Extraction Point
Caution, risk of injury!
When shortening the suction tube, please ensure that the
integrated wire is cut as straight as possible.
Long suction hoses, tight bends and kinks will considerably
reduce the extraction force at the extraction point.
⇒ If necessary, shorten the suction hose�
⇒ Open the Velcro® strip (7)�
⇒ Place the suction hose with the end mufflers (12) into the
suction port (6)�
⇒ Fasten the suction hose with the Velcro® strip�
⇒ Connect the suction hose to the suction port on the CAM de-
vice� Please observe the CAM device instructions for use�
If the diameter size does not correspond, please use an
adapter (see accessories) to prevent a loss in suction per-
formance.
Avoid steep pitches or hanging points along the hose path.
min 100 mm,
- 8 -
6
12
7
Fig. 3