5.
To activate compression, grasp pull-handle and pull straight out from the
torso. After the desired level of compression has been achieved, fasten the
pull handle to anterior portion of the compression panels. Adjust compression
after five minutes, then re-adjusting as needed (Figure E).
REMOVAL OF BRACE:
1.
Release the compression handles and remove one of the shoulder straps.
2.
Release one side of the side panel from front panel and slide the orthosis off
the other shoulder like removing a jacket or backpack.
CUSTOMIZING TLSO: (To be performed by a licensed medical professional only)
Waist Belt: If needed, to modify the waist belt, adjust the side panels by
un-hooking the Velcro on the backpanel and moving panels more center for a
smaller waist, or closer to the edge of the back panel for a larger waist.
Shoulder Straps: If needed, the extra length in the straps can be trimmed
with scissors.
Sternal Bar: May be bent as needed by using a stable edged of a table. Using
both hands, bend the bar in a slow and controlled fashion to adjust to desired
degree of offset. The stock sternal Y-bar is set at 15°.
HOT/COLD PACK (SOLD SEPARATELY)
1.
Follow instructions on hot/cold pack. Insert hot/cold pack into pocket and
adhere to back panel.
ADJUSTING PULL TAB LENGTH (OPTIONAL)
1.
Remove lace spool from the pull tab pocket and wind lace around the spool to
shorten the length of the pull tab. Unwind lace from the spool to lengthen the
pull tab. (Figure F)
2.
Insert lace spool back into pull tab pocket.
INSERT/REMOVE FRONT PANEL
1.
Open inside panel pocket. Remove semi-rigid panel. (Figure G)
2.
Open inside panel pocket and insert semi-rigid panel.
CLEANING INSTRUCTIONS: Separate the brace's removable REAR PANEL
before cleaning.
Hand wash in water
NOTE: If not rinsed thoroughly, residual soap may cause irritation and
deteriorate material.
Do NOT iron.
Do NOT tumble dry.
Do NOT bleach.
MATERIAL CONTENTS: Nylon, Polyester, Polyurethane, Polyethylene, Acrylic,
Polypropylene, PVC, Synthetic Rubber, EVA, Aluminum, Steel, Glass, Acetal, Calcium
Carbonate
WARRANTY: DJO, LLC will repair or replace all or part of the unit and its
accessories for material or workmanship defects for a period of six months from
the date of sale. To the extent the terms of this warranty are inconsistent with
local regulations; the provisions of such local regulations will apply.
FOR SINGLE PATIENT USE ONLY
RX ONLY
LATEX
PRODUCT NOT MADE WITH NATURAL RUBBER LATEX
NOTICE: WHILE EVERY EFFORT HAS BEEN MADE IN STATE-OF-THE-ART TECHNIQUES TO
OBTAIN THE MAXIMUM COMPATIBILITY OF FUNCTION, STRENGTH, DURABILITY AND
COMFORT, THERE IS NO GUARANTEE THAT INJURY WILL BE PREVENTED THROUGH THE USE OF
THIS PRODUCT .
(86°F/30°C)
, using mild soap. Air dry.
3