Overflow valve with two pressure
switches
– While reducing the water supply at the
pump head or with the Servopress -
regulation the overflow valve opens and
part of the water flows back to the pump
suck side.
– If the hand-spray gun is closed, so that
the whole water flows back to the pump
suck side, the pressure switch at the
overflow valve shuts down the pump.
– If the hand spray gun is opened, the
pressure switch on the cylinder head
turns the pump back on.
The overflow valve is set by the manufac-
turer and sealed. Setting only by customer
service.
Safety valve
– The safety valve opens, when the over-
flow valve resp. the pressure switch is
broken.
The safety valve is set by the manufacturer
and sealed. Setting only by customer ser-
vice.
Water shortage safeguard
– The water shortage safeguard prevents
the burner to be turned on when there is
water shortage.
– A sieve prevents the contamination of
the safeguard and must be cleaned reg-
ular.
Temperature stop for exhaust gases
– The temperature stop switches off the
machine when the waste gases have
reached very high temperatures.
Start up
WARNING
Risk of injury! Appliance, accessories, sup-
ply lines and connections must be in fault-
free condition. If they are not in a perfect
state then the appliance must not be used.
Lock parking brake.
All manuals and user guides at all-guides.com
Figure 3
ATTENTION
Hook the electric supply line into the cable
guide of the right handle bow. Be careful
not to damage the cable.
Figure 4
Note: To protect the device, the burner is
switched off 5 hours after the system care
container is empty.
– The system care prevents the calcifica-
– The metering is set to medium water ri-
Note: A sample bundle of system care is in-
cluded.
Refill system care.
Adjusting the dosage of the system
Determining the hardness of tap water:
– through the public water supply works,
– using a hardness tester (order no.
Water hard-
ness (°dH)
<3
3...7
7...14
14...21
>21
Set the service switch according to the
Note: Observe the following when using
system care Advance 2 RM 111:
– Calcification protection: See table
– Pump care and black water protection:
– 4
EN
Installing the handle
Attach the wheel caps
Refill system care
tion of the heating spiral while operating
with calciferous tap water. It is dosed
into the supply in the float container
drop by drop.
gidity by the manufacturer
care Advance RM 110/RM 111
6.768-004)
Scale on the service switch
OFF (no dosing)
1
2
3 (presetting)
4
water hardness in the table.
Set the service switch to at least setting
3.