1.8.3

Fuel Conversion, 20RESA/RESAL

For LPG fuel, an orifice is used in the fuel line. The unit is
typically shipped set up for natural gas, with the loose
orifice tied near the fuel solenoid valve. To convert to
LPG, install the LPG orifice as described below. See
Figure 1-13 for the fuel system component locations.
Note: The generator set harness may contain a pair of
DSAI leads near the fuel solenoid valve.
Connecting or disconnecting these leads has no
effect on the 20RESA/RESAL operation.
Procedure to Convert from NG to LPG,
20RESA/RESAL
1. Press the OFF button on the generator set
controller.
2. Disconnect the power to the battery charger.
3. Disconnect the generator set engine starting
battery, negative (--) lead first.
4. Turn off the fuel supply.
5. Remove the hose clamp and fuel hose from the
hose fitting. See Figure 1-13.
6. Insert the LPG orifice into the hose fitting. See
Figure 1-13.
7. Slide the hose onto the hose fitting and secure it
with the clamp.
8. Connect and turn on the new fuel supply.
9. Reconnect the generator set engine starting
battery leads, negative (--) lead last.
10. Reconnect power to the battery charger.
11. Start the generator set by pressing the RUN button
on the generator set controller.
12. Check for leaks using a gas leak detector.
13. Run the generator set and check the operation.
14. Press the OFF button to shut down the generator
set.
Conversion from LPG to Natural Gas
To convert from LPG to natural gas, repeat the steps
above to remove the LPG fuel orifice.
20
Section 1 Installation
All manuals and user guides at all-guides.com
Figure 1-13 Fuel Regulator and LPG Orifice,
1.8.4
Model 20RESA/RESAL generators are equipped with
fuel regulator vent hoses. Drill or punch two holes in the
enclosure at the locations shown on the template in
Appendix B. It may be convenient to cut openings for the
electrical leads at the same time as shown on the
template and in Section 1.9.2.
Insert the open ends of the hoses through the holes to
the outside of the enclosure as shown in Figure 1-14.
Figure 1-14 Fuel Regulator Vent Hoses
LPG setup
shown
1
2
1. LPG orifice
2. Hose fitting
3. Regulator
4. Regulator vent tubes (vent to the outside of the controller)
20RESA/RESAL

Regulator Vent Hose

1. Fuel regulator vent tubes, qty. 2
2. Drill or punch two holes and route both hoses to the outside
of the enclosure
3
GM84143
4
1
2
sb722
TP-6803 1/15