Generator Set Model
14RESA/RESAL
Figure 5-4 Spark Plug Gap
Figure 5-5 Checking the Spark Plug Gap
Figure 5-6 Adjusting the Spark Plug Gap
TP-6804 1/15
Spark Plug Gap
0.76 mm (0.030 in.)
1--514
1--511
5.4 Air Cleaner Service
WARNING
Fire.
Can cause severe injury or death.
Do not smoke or permit flames or
sparks near fuels or the fuel system.
Servicing the air cleaner. A sudden backfire can cause
severe injury or death. Do not operate the generator set with
the air cleaner removed.
5.4.1
Air Cleaner, 14RESA/RESAL
The engine has a replaceable high-density paper air
cleaner element. See Figure 5-7.
1
2
3
4
5
6
1. Cover knob
2. Air cleaner cover
3. Element cover nut
4. Element cover
5. Air cleaner element
6. Air cleaner base
Figure 5-7 Air Cleaner Components
Check for a buildup of dirt and debris around the air
cleaner system. Keep this area clean. Also check for
loose or damaged components. Replace all bent or
damaged air cleaner components.
Note: Operating the engine with loose or damaged air
cleaner components could allow unfiltered air
into the engine causing premature wear and
failure.
Section 5 Scheduled Maintenance
586536
67