Switching off

1.
Restore the gas lever (A - 5) to its original position.
Set the engine switch (A - 4) to the "OFF" position.
2.
The motor pump stops.
3.
Drain the motor pump then rinse it (see § Rinsing) if its use is over for the day.
Always ensure suitable ventilation for the motor pump.
Even after shut down, the engine continues to give off heat
Warning
4.5
Rinsing
Once the motor pump is shutdown and cold:
1.
Empty the suction & discharge hoses, allow the liquid to drain out.
2.
Unscrew the drain plug from the pump (A - 8) in order to drain-out the pump housing (E - 1).
3.
Screw the pump drain plug back on once drainage is complete.
4.
Remove the pump filler plug (A - 2) and fill the pump housing with clean water.
5.
Slowly pull the recoil starter handle several times (A - 7) till encountering resistance, allow it to return back gently.
6.
Unscrew the pump drain plug and drain the pump housing.
7.
Screw the pump fill & drain plugs back on.
8.
Clean the strainer.
5

Maintenance schedule

5.1
Reminder of use
All maintenance operations are to be carried out as described in the maintenance table. Their frequency is given for your
information, for the motor pumps operating with fuel or oil in accordance with the specifications given in this manual.
If the motor pump is used under extreme conditions, reduce the interval between maintenance operations.
5.2
Maintenance table
Operations to be
Component
whichever deadline
is reached first
Fixings
Pipes, fittings,
strainer, clamps
Check the level
Engine oil
Air filter
Decanting bowl
Glow plug
Motor pump
Spark arrester
Check – Adjust*
Idle speed
Check – Adjust*
Valve clearance
Combustion
chamber
Fuel tank and fuel
filter
Fuel pipe
* Operation(s) must only be carried out by one of our agents.
(1) Only replace the paper element.
The air filter must be cleaned more frequently if the generating set is being used in a dusty environment.
carried out at
1
first 20 hours
Check
6
Check
6
Change
6
Check
Clean
3
Replace
12
Clean
6
Check/Adjust
6
Replace
12
Clean
6
Clean*
6
12
12
Clean*
Clean*
6
Check*
24
After:
st
month
Each time
or
it is used
50 hours
Every 500 hours
Replace if necessary
16/120
Every
Every
100 hours
Every
300 hours
(1)