Descargar Imprimir esta página

Operating Instructions; Symbols Used; Safety Instructions; Notes For The Use Of Air-Conditioners - Truma Saphir vario Instrucciones De Uso

Ocultar thumbs Ver también para Saphir vario:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
Air-conditioning unit Saphir vario
Table of contents
Symbols used ....................................................................... 12
Safety instructions ........................................................... 12
Notes for the use of air-conditioners ............................ 12
Remote control ..................................................................... 13
Taking into operation ............................................................ 13
Switching off ........................................................................ 13
Timer off ............................................................................... 13
IR receiver and manual on / off ............................................ 13
Operating indicator .............................................................. 13
Red LED illuminates ............................................................. 13
Maintenance ...................................................................... 14
Trouble-shooting .................................................................. 14
Changing the battery in the remote control ........................ 14
Disposal .............................................................................. 14
Accessories ........................................................................ 14
Operating mode 1 ................................................................ 15
Operating mode 2 ................................................................ 15
Operating mode 3 ................................................................ 16
Technical data .................................................................... 16
Installation dimensions ........................................................ 16
Manufacturer's terms of warranty ................................ 17
Intended use ......................................................................... 17
Approval ............................................................................... 17
Provisions ............................................................................. 17
Location selection ............................................................. 17
Installing the air conditioning unit ................................. 18
Cold air distribution .............................................................. 19
Circulating air return ............................................................. 19
Installing the infra-red receiver ...................................... 19
connection .......................................................................... 20

Symbols used

Symbol indicates a possible hazard.
Comment including information and tips.

Safety instructions

Repairs may only be carried out by properly qualified
professionals!
In order to avoid transport damage, the device must not be
sent until the Truma Service Centre has been contacted.
The voltage must be disconnected at all poles before the
housing is opened.
The 230 V, T 5 A H-type (slow, IEC 127) fuse in the unit can
be found on the electronic control unit and must always be
replaced with an identical fuse.
Appliance fuses and connection leads may only be replaced
by a properly qualified person.
Any modifications to the device or the use of spare parts and
accessories that are important to the operation of the system
that are not original Truma parts and failure to follow the
12
installation and operating instructions will cancel the warranty
and indemnify Truma from any liability claims.
The refrigerant circuit contains R 407C and R 134a refrigerant
and must only be opened in the factory.
The cool air outflow and the ambient air suction intake must
not on any account be obstructed. Please bear this in mind in
order to ensure the trouble-free operation of your device.
The apertures beneath the vehicle floor must be kept free of
dirt and snow slush. The apertures must not be located within
the area subject to spray from the wheels or mudguards.
Splash protection must be provided if necessary.
If the floor of the vehicle is provided with underfloor protec-
tion, all the apertures beneath the vehicle must be covered in
order to prevent the spray created from penetrating the
device and causing malfunctions. Once the work has been
completed the covers can be removed again.
In order to avoid damage to the compressor, when the device
is in operation during transit (for example, with the genera-
tor or voltage transformer working), do not attempt uphill or
downhill gradients of more than 8 %.
Do not allow cooling operation to run for extended periods in
a tilted position, since the condensation water which forms
may not be able to run off, and in the worst scenario might
penetrate into the vehicle.
For problem-free operation and in order to avoid damage, the
supply voltage must always come from a source with a sine
wave curve (e.g. voltage converter, generator) and without
voltage spikes.
When the floor of the vehicle is being cleaned, it must be en-
sured that no water penetrates the openings in the base of the
unit when spraying with a high-pressure cleaner, for example.

Notes for the use of air-conditioners

-
The Saphir vario air conditioning unit is designed for mini-
mal power consumption. Nevertheless, you should check
before taking the system into operation whether the camp-
ing site has adequate fuses (min. 1.7 A).
-
As far as possible, park your vehicle in the shade.
-
Darkening the interior with window blinds and / or a roof
awning will reduce the penetration of radiant heat.
-
Clean the roof of the vehicle regularly (dirty roofs heat up
more readily).
-
Before operating the device, ventilate your vehicle thor-
oughly, in order to allow the hot air which builds up inside
to escape.
-
Take care when putting up awnings or similar that there
are sufficient openings for the supply air to be discharged.
The opening for the hot discharge air should not be on the
intake side.
-
To create a healthy environment on the inside of the vehicle,
the difference between the inside and outside temperatures
should not be selected as too great. During operation the
circulated air will be purified and dried. Due to the drying of
the moist, humid air, a pleasant environment will be created
inside even with slight temperature differences.
-
Keep the doors and windows closed while the cooling
system is in operation.
If a single room such as a bedroom is being cooled
with 600 W, the two outlets that are not required must
be closed, otherwise the cooling power will be distributed
throughout the entire vehicle.

Publicidad

loading