Electrical installation
Install battery pack:
1. Loosen the screw (Fig. C 1).
2. Remove the lid (Fig. C 2) of the battery box.
3. When changing the battery pack, disconnect the cable connector (Fig. C 5)
and remove the empty battery pack from the battery box.
WARNING
► Use only the Dräger LBT 05** (see "Accessories and spare parts", page 52)
battery pack.
4. Open the seal on the new battery pack and connect the cable plug of the
battery pack (Fig. C 5).
The cable plug of the battery pack must engage when plugged in.
5. Insert the battery pack in the battery box.
When closing the battery box, pay attention to the cable to avoid
damage.
6. Reattach the battery box lid.
7. Tighten screw (Fig. C 1).
Subsequent activities:
Install the battery box.
6.2.3

Installing the battery box

Prerequisites:
The gas detector is open.
Insert the battery pack into the battery box.
Install the battery box:
1. Connect grounding cable to fastening screw for potential equalization (Fig.
A 17).
WARNING
► Use only the Dräger LBT 03**(see "Accessories and spare parts", page 52)
battery box.
2. Insert battery box (Fig. A 2).
3. Close the gas detector:
40
Subsequent activities:
NOTICE
► If the same battery pack is refitted, do not reset the battery counter.
6.2.4
Can be performed within 10 minutes of switching on the gas detector.

Resetting the battery counter:

● Hold magnetic pin onto mark (Fig. A 12) for 5 seconds.
✓ The battery counter is reset.
Instructions for use
|
Dräger Polytron
a. Place the housing cover (Fig. A 1) in its final position (Dräger logo is
horizontal).
b. Turn the housing cover under slight pressure approx. 20°
counterclockwise until the housing cover rests on the sealing ring on the
housing.
c. Press the housing cover forcefully and evenly onto the sealing ring.
d. Slowly turn the housing cover approx. 20° clockwise to the stop in the
end position.
e. Screw in the locking screw (Fig. A 14) until the housing cover is
prevented from being screwed open.
If a new battery pack has been inserted, reset the battery counter.
Resetting the battery counter
 Blue and yellow LEDs are activated simultaneously for 5 seconds.
This feature is also available in PolySoft. It can be executed at any time.
®