Maintenance; Technical Data - SICK WTB16 Manual Del Usuario

Ocultar thumbs Ver también para WTB16:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
11

MAINTENANCE

11
Maintenance
en
12

Technical data

Sensing range max.
Light spot size / distance
Supply voltage U
B
Ripple
Current consumption
Output current I
max.
Max. response time
Switching frequency
Enclosure rating
6)
Protection class
Circuit protection
32
O P E R A T I N G I N S T R U C T I O N S | WTB16
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
This SICK sensor is maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
Clean the optical interfaces using a plastic cleaner, do not use acetone or methy‐
lated spirits.
Check the fittings and plug connectors
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
WTB16P-xxxxx1,
WTB16P-xxxxx2
10 mm ...
1,000 mm (type)
1)
Ø 3 mm (200 mm)
(type), Ø 6 mm
(500 mm) (type)
DC 10 ... 30 V
≤ 5 V
SS
≤ 30 mA
2)
< 50 mA
3)
≤ 100 mA
500 µs
4)
1000 Hz
5)
see table
7:
x4, xH, x5, xI: IP66,
IP67, IP69
7)
x9, xB: IP65
III
A, B, C, D
8)
WTB16P-xxxxx4
WTB16I-xxxxx1
10 mm ...
10 mm ... 1,500
1,600 mm
mm
1)
1)
Ø 6 mm (500 mm)
Ø 12 mm (800
mm)
DC 10 ... 30 V
DC 10 ... 30 V
≤ 5 V
≤ 5 V
SS
SS
≤ 30 mA
2)
≤ 30 mA
< 50 mA
< 50 mA
3)
≤ 100 mA
≤ 100 mA
2.5 ms
500 µs
4)
4)
200 Hz
1000 Hz
5)
see table
7:
see table
x4, xH, x5, xI: IP66,
x4, xH, x5, xI: IP66,
IP67, IP69
IP67, IP69
7)
x9, xB: IP65
x9, xB: IP65
III
III
A, B, C, D
A, B, C, D
8)
WTB16I-xxxxx4
10 mm ...
1,900 mm
1)
Ø 12 mm (800
mm)
DC 10 ... 30 V
≤ 5 V
SS
2)
≤ 30 mA
2)
< 50 mA
3)
3)
≤ 100 mA
2.5 ms
4)
200 Hz
5)
5)
7:
see table
7:
x4, xH, x5, xI: IP66,
IP67, IP69
7)
7)
x9, xB: IP65
III
A, B, C, D
8)
8)
8020346.1DS6/2021-11-24 | SICK
Subject to change without notice

Publicidad

Tabla de contenido
loading

Tabla de contenido