3.6 Multifunction button
For versions Professional(+) 7,4 / 22 (PnC) only.
The residual current device and the miniature circuit
breaker in the device can be manually switched on again
from outside via the multifunction button. The residual
current device can be tested for functionality using the
multifunction button without opening the housing.
Fig. 8: Multifunction button
3.7 Operating modes
The device has various operating modes that can be
changed even during operation.
The availability of the individual operating modes
depends on the configuration of the device.
The following operating modes are possible:
"Autostart"
The device is operated as a stand-alone solution wit-
hout connection to a Backend-System. An authorisati-
on is not required.
"Local Whitelist"
The device is operated as a stand-alone solution wit-
hout connection to a Backend-System. Authorisation
occurs via RFID cards and a local Whitelist.
"Backend-System"
The device is connected to the Backend-System via
OCPP. The device is operated via the Backend-System.
"Networked"
Several devices are connected via ethernet to ena-
ble use of local load management and to establish a
connection to the Backend-System for all networked
devices.
Requirements:
9
The accessory kit for local networking of multiple
devices is installed.
9
Multiple devices are networked.
Installation manual of the accessory kit.
3.8 LED Info bar
The LED information field indicates the operating status of
the device. Standby, charging, wait time, and fault are indi-
cated by four symbols in the colours blue, green, white,
and red.
Symbol
Colour
Lights
Standby
up blue
The device is ready for use. No
vehicle is connected to the device.
flashes
Standby: Starting the charging
blue
process
Authorisation has occurred.
Authorisation has not occurred.
Lit
Charging
green
Charging in progress.
flashes
Charging: Excess temperature
green
warning
Charging in progress. The device
reduces the charging current to
prevent overheating and deacti-
vation.
steady
Wait period
white
The charging process on the
Waiting for authorisation.
flashes
Wait time: Removing the char-
white
ging cable
The charging process has finished.
Remove the charging cable.
lit or
Fault
flashing
A fault prevents the vehicle from
red
charging.
Î "9 Remedy"
Operating state
No vehicle is connected to the
device.
A vehicle is connected to the
device.
device was ended. Waiting for
confirmation from the vehicle.
EN