5.5 Mounting the device on the wall
At low sub-zero temperatures, the
device should be stored at room temperature for
24 hours before installation and commissioning.
For interim storage the device must be stored at
room temperature.
T
ATTENTION
Device damage due to an uneven surface
If the device is mounted on an uneven surface the lower
enclosure part can warp. In this case the specified protec-
tion class is no longer ensured. Consequential damage of
electronic components can occur.
f Only mount the device on level surfaces.
f If necessary, level out uneven surfaces with suitable
measures.
MENNEKES recommends mounting at an ergo-
nomically sensible height depending on the
height of the body.
Fig. 10: Drilling dimensions [mm]
f Mark the mounting bores using the supplied drilling
template or Fig. "Fig. 10: Drilling dimensions [mm]".
The provided fastening material (screws, dowels)
are only suitable for installation on concrete
walls, brick walls and wood walls.
f Drill holes in the wall with the diameter required by
selected mounting material.
f Introduce the line into the device through a cable
entry. To do this, you need to make a hole in the
respective membrane.
Approx. 30 cm of cable are required for the sup-
ply line inside the device.
To prevent the ingress of rainwater,
the hole in the membrane should not be larger
than the cables.
Fig. 11: Attach to the wall
f Fasten the device to the wall using dowels (1), screws
(2) and sealing plugs (3).
EN