Hostname (binary
OCPP)
Port number (binary
OCPP)
WebSockets JSON
OCPP URL of the
Backend
WebSockets keep-
alive interval
HTTP Basic
Authentication pass-
word
Tcp Watchdog
Timeout
Enable cache
List of entries in
cache
Cache expiry mode
Cache learning mode
Local fixed authoriza-
tion list (FLL)
List of entries in FLL
FLL learning mode
24
DNS host name or IP address of the
binary OCPP proxy server for the
Backend-System
TCP port of the proxy server for
binary communication with the
Backend-System
WS / WSS-URL of the OCPP
Backend-System
WebSockets keep-alive interval (in
seconds)
Password for HTTP Basic
Authentication
Time until a restart will be exe-
cuted, after the connection to the
Backend-System has been inter-
rupted or could not be restored
Setting that specifies whether an
internal cache will be used for the
RFID-UID
Listing of the RFID-UIDs present in
the internal cache
The expiration date of cache ent-
ries, if the OCPP expiration date has
not been specified by the Backend-
System
Activates the teaching of RFID UIDs
via the RFID card reader. The ent-
ries are stored in the internal cache.
Setting that specifies whether a
local authorization list will be used
for the RFID-UIDs
Listing of the RFID-UIDs in the local
authorization list
Activates the teaching of RFID UIDs
via the RFID card reader. The ent-
ries are stored in the local authori-
zation list.
This setting input box must remain empty
Charging
system
Preset: "444"
Only for "OCPP-J 1.6".
ID of the charging point is automati-
cally attached when connecting to the
Backend-System
The value "0" prevents the keep-alive
interval
Backend-
Information will be provided by your
System
Backend-System provider
Only if "Connection type" = "Ethernet"
An empty field prevents the HTTP
Basic Authentication.
Information will be provided by your
Backend-System provider
The value "0" prevents a restart of the
Charging
device
system
"Off": RFIDs will not be added to the inter-
nal cache
Syntax: UID1:UID2:UID3 ...
Max. 80 RFID-UIDs
Preset: 2038 (latest permissible time)
The function remains active for 5 minutes
Authori-
zation
Syntax: UID1:UID2:UID3 ...
Max. 80 RFID UIDs are displayed
The function remains active for 5 minutes