Firmware Update; Remedy; Fault Messages - Mennekes AMTRON Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
T
ATTENTION
Material damage due to incorrect cleaning
Incorrect cleaning can cause damage to the housing or
components.
f Do not use running water and ensure that water can-
not reach live parts.
f Do not use high-pressure cleaning devices.
f Only use tools (e.g. brushes, cleaning agents) that are
suitable for plastic surfaces.
f Do not use aggressive cleaning agents or chemicals.
The device can be cleaned with a dry or damp cloth,
depending on application conditions and soiling. The
cleaning is carried out exclusively from the outside.
Procedure:
f First remove coarse dust and contamination with a
hand brush with soft bristles.
f If necessary, moisten a clean cloth that is suitable for
plastic surfaces with water and thoroughly wipe off the
device.
f Only clean the charging cable when it is unplugged.

8.3 Firmware Update

The firmware is subject to ongoing further development;
this means that after some time new firmware updates are
available.
You can obtain the current software from MENNEKES on
request.
Î "1.1 Service"
37

9 Remedy

If a fault occurs the "Fault" symbol lights up or flashes on
the LED information panel. The device cannot be used as
long as the fault has not been rectified.
Possible faults:
„ Wrong or defective charging cable.
„ For versions Professional(+) 7,4 / 22 (PnC) only:
Residual current device or circuit breaker has trig-
gered.
To correct the fault, observe the following sequence:
f Terminate the charging process and disconnect the
charging cable.
f Check whether the charging cable is suitable.
f Plug the charging cable back in and start the charging
process.
f For versions Professional(+) 7,4 / 22 (PnC) only: Restart
residual current device or circuit breaker.
Î "7.3.1 Restarting residual current device and circuit
breaker"
If the fault could not be corrected, contact your
responsible service partner.
Î "1.1 Service"
9.1

Fault messages

The tasks described below may only be carried
out by a qualified electrician.
The error message can be viewed via the web interface.
9
A network connection is established.
Î "6.1 Setting up a connection to the ECU"
Reading out an error message
f In the web browser, at http://192.168.123.123/operator,
navigate to "State".
f In the "Errors list" row, the error message is displayed
in the second column.