Fault
Emergency Stop signal
Cable assembly cannot
be introduced into the
iCAT WH
Hose assembly makes
ripples in the robot axis
Inexact torch reset
Gas loss
Tab. 12
Troubleshooting
Cause
• Cable assembly connected
incorrectly
• Play of cable assembly too small
between feeder and iCAT WH
• Control lead, cable assembly or
board defective
• Cable assembly mounted under
torsion
• No grease on the O-rings of the
adapter
• No grease in the mounting bores
of the liquid-cooled cable
assembly adapter
• Cable assembly too long
• Dirt deposits in the housing
• iCAT WH damaged
• Liner diameter to large
• Liner insufficiently stripped on the
torch side
10 Troubleshooting
Solution
• See cable assembly fastening
 Page EN-16
• Change the feeding system
positioning, if possible
• Have it checked and replaced by
qualified personnel
• Unscrew cable assembly from
feeder and reconnect it free of
torsion.
• Lubricate the O-rings with grease
• Grease the bores
• Change the feeding system
positioning, if possible
• Remove dirt deposits, clean
housing
• Verification by qualified personnel
• Use a smaller liner
• Strip liner 350 mm on the torch
side