Putting Out Of Operation; Maintenance And Cleaning - Abicor Binzel iCAT WH Instructivo De Servicio

Soporte para robot
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

8 Putting out of operation

8 Putting out of operation
Putting out of operation depends on the respective welding torch.
Please observe the operating instructions of the respective ROBO WH welding torches.

9 Maintenance and cleaning

Scheduled maintenance and cleaning is a prerequisite for a long life and a trouble-free
operation.
DANGER
Risk of injury due to unexpected start
The following instructions must be adhered to throughout all maintenance, servicing,
assembly, disassembly and repair work:
• Switch off the power source.
• Close off the coolant supply.
• Close off the compressed air supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
NOTICE
• The maintenance intervals given are standard values and refer to single-shift operation.
• Only qualified personnel are permitted to perform work on the device or system.
• Always wear your personal protective equipment when performing maintenance and
cleaning work.
• When replacing the liquid-cooled ROBO WH cable assemblies, make sure that any
coolant residues are removed from the iCAT ROBO WH by blowing compressed air
through it.
EN - 20
iCAT WH

Publicidad

Tabla de contenido
loading

Tabla de contenido