Outdoor model
Function
Power supply
Capacity Rated frequency(Min.-Max.)
Dehumidification
Air flow ✽1
Power outlet
Running current ✽1(Total)
Power input ✽ 1(Total)
Power factor ✽ 1 (Total)
Starting current ✽1(Total)
Compressor motor current ✽1
Fan motor current ✽ 1
Coefficient of performance(C.O.P)
Model
Compressor
Output
Fan motor Model
Dimensions WxHxD
Weight
Sound level ✽1
Fan speed
Fan speed regulator
Refrigerant filling
capacity(R410A)
Refrigeration oil (Model)
NOTE: Test conditions are based on ISO 5151
Cooling : Indoor
Outdoor Dry-bulb temperature 35
Heating : Indoor
Outdoor Dry-bulb temperature 7
Refrigerant piping length (one way): 5m
✽1 Measured under rated operating frequency
MUZ-HC25VA
Cooling
2.5 (0.9-3.0)
kW
1.4
/h
1,812
/h
A
3.7
A
770
W
90
%
A
4.2
3.24
A
A
✽1 (Total)
3.25
KNB065FDTH(C)
W
500
mm
kg
46
dB(A)
810
rpm
0.73
kg
cc
Dry-bulb temperature 27
°C
°C
:
Dry-bulb temperature 20
°C
°C
MUZ-HC35VA
Heating
Cooling
Single phase
230V,50Hz
3.15 (1.0-3.7)
3.2 (0.9-4.4)
2.0
-
1,800
1,788
10
4.8
4.2
980
880
89
91
4.8
4.34
3.74
0.24
3.21
3.64
RA6V21-AB or BB
684x540x255
25
47
47
800
800
1
320 (NEO22)
Wet-bulb temperature 19
°C
Wet-bulb temperature 6
°C
Especifi caciones
MUZ-HC35VAB
Heating
Cooling
3.6 (0.9-4.8)
3.4 (1.0-3.7)
-
2.0
1,776
1,800
4.8
5.3
995
1130
90
93
5.3
4.34
4.84
3.62
3.01
KNB073FEDH or FGDH
550
48
47
790
800
0.75
Heating
3.6 (0.9-4.8)
-
1,776
4.8
995
90
4.34
3.62
48
790
251