Mitsubishi Electric Mr. SLIM MSZ-FA25VA Technical Manual página 433

Ocultar thumbs Ver también para Mr. SLIM MSZ-FA25VA:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MXZ-3A/4A/5A
Indication
Symptom
No.
LED1(Red) LED2(Yellow)
Outdoor unit
Lightning
Once
does not
1
operate.
2
Lightning
Twice
3
Lightning
3 times
4
Lightning
4 times
5
Lightning
5 times
6
Lightning
7 times
7
Lightning
8 times
8
Lightning
10 times
9
Lightning
11 times
10
Lightning
12 times
'Outdoor unit
stops and
restarts 3
Twice
Goes out
11
minutes
later' is
repeated.
3 times
Goes out
12
4 times
Goes out
13
14
5 times
Goes out
15
8 times
Goes out
16
9 times
Goes out
17
13 times
Goes out
18
Lighting
8 times
19
Lighting
11 times
Lighting
12 times
20
NOTE 1. The location of LED is illustrated at the right figure. Refer to 13-7.1.
2. LED is lighted during normal operation.
The flashing frequency shows the number of times the LED blinks after every 2.5-second OFF.
(Example) When the flashing frequency is "2".
ON
2.5-second OFF
OFF
Abnormal point / Condition
LEV for drain
When the indoor unit detects any abnormality in the LEV for drain.
When over current protection stop is continuously performed three times
within 1 minute after the compressor gets started, or when converter
Outdoor power system
protection stop or bus-bar voltage protection stop is continuously performed
three times within 3 minutes after start-up.
When a short circuit is detected in the thermistor during operation, or
Discharge temperature
when an open circuit is detected in the thermistor after 10 minutes
thermistor
of compressor start-up.
Fin temperature
thermistor
When a short or open circuit is detected in the thermistor during
operation.
P.C board temperature
thermistor
Ambient temperature
When a short or open circuit is detected in the thermistor during
thermistor
operation.
When a short circuit is detected in the thermistor during operation, or
Outdoor heat exchanger
when an open circuit is detected in the thermistor after 5 minutes (in
temperature thermistor
cooling) and 10 minutes (in heating) of compressor start-up.
When a short circuit is detected in the thermistor during operation, or
Defrost thermistor
when an open circuit is detected in the thermistor after 5 minutes of
compressor start-up.
When the nonvolatile memory data cannot be read properly.
Nonvolatile memory data
Current sensor protection stop is continuously performed twice.
Current sensor
Gas pipe temperature
thermistor A
Gas pipe temperature
thermistor B
When a short or open circuit is detected in the thermistor during
cooling.
Gas pipe temperature
(A,B,C : MXZ-3A54/4A71/4A80)
thermistor C
(D
: MXZ-4A71/4A80)
Gas pipe temperature
thermistor D
When the communication protection stop between boards is
Communication error
between P.C. boards
continuously performed twice.
The protection stop of the zero cross detecting circuit is continuously
Zero cross detecting
performed 10 times.
circuit
IPM protection
When over-current is detected after 30 minutes of compressor start-up.
When over-current is detected within 30 minutes of compressor
Lock protection
start-up
Discharge temperature
When discharge temperature exceeds 116 °C
protection
can restart if discharge temperature thermistor reads 100
minutes later.
Fin temperature
When the fin temperature exceeds 87 °C during operation.
protection
P.C. board temperature
When the P.C. board temperature exceeds 70 °C during operation.
protection
High-pressure
When high-pressure is detected with the high-pressure switch (HPS)
protection
during operation.(MXZ-4A80)
When the outdoor heat exchanger temperature exceeds 70 °C
during cooling or when indoor gas pipe temperature exceeds 70 °C
during heating.
Converter protection
When a failure is detected in the operation of the converter during
operation.
Bus-bar voltage
When the bus-bar voltage exceeds 400V or falls to 200V or below
during compressor operating.
protection (1)
When the bus-bar voltage exceeds 400V or falls to 50V or below
Bus-bar voltage
protection (2)
during compressor operating.
When failure occurs continuously three times within 30 seconds after
Outdoor fan motor
the fan gets started.
Current sensor
When a short or open circuit is detected in the current sensor during
protection
compressor operating.
Communication between P.C.
Communication error occurs between the outdoor electronic control P.C.
board and power board for more than 10 seconds.(MXZ-3A54/4A71/4A80)
boards protection
When zero cross signal cannot be detected while the compressor is
Zero cross detecting circuit
operating.
protection
Condition
during operation. Compressor
°C
or less 3
0.5-second ON
2.5-second OFF
Resolución de averías
Correspondence
• Refer to 13-6.D "Check of LEV".
• Check the drain pump of the indoor unit.
• Check the connection of the compressor connecting
wire.
• Refer to 13-6.E "How to check inverter/compressor".
• Check the stop valve.
• Refer to 13-6.F "Check of outdoor thirmistors".
• Refer to 13-6.F "Check of outdoor thirmistors".
• Replace the outdoor electronic control P.C. board.
• Refer to 13-6.F "Check of outdoor thirmistors".
• Replace the outdoor electronic control P.C. board.
• Replace the power board.
• Refer to 13-6.F "Check of outdoor thirmistors".
• Check the connecting wire between outdoor electronic control
P.C. board and power board.
• Check the connecting wire among outdoor electronic control
P.C. board, noise filter P.C. board and power board.
• Reconnect compressor connector.
• Refer to 13-6.E "How to check inverter/compressor".
• Check the stop valve.
• Check the power module (PAM module).
• Check the amount of gas and refrigerant circuit.
• Refer to 13-6.D "Check of LEV".
•Check refrigerant circuit and refrigerant amount.
•Refer to 13-6.G "Check of outdoor fan motor".
• Check around of gas and the refrigerant circuit.
• Check of stop valve.
• Replace the power board.
• Replace the power board.
• Refer to 13-6.G "Check of outdoor fan motor".
• Replace the power board.
• Check the connecting wire between outdoor electronic control
P.C. board and power board.
• Check the connecting wire among outdoor electronic control
P.C. board, noise filter P.C. board and power board.
Outdoor electronic control P.C. board(Parts side)
Lighting
0.5-second ON
LED2 LED1
433

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mr. slim msz-fa35vaMr. slim muz-fa25vaMr. slim muz-fa35vaMr. slim msz-ga22vaMr. slim msz-ga25vaMr. slim msz-ga35va ... Mostrar todo

Tabla de contenido