MXZ-3A54VA
Indoor units
Unit A
combination
22
2.2
25
2.5
35
3.5
50
5.0
22+22
2.2
22+25
2.2
22+35
2.08
22+50
1.65
25+25
2.5
25+35
2.25
25+50
1.8
35+35
2.7
35+50
2.22
50+50
2.7
22+22+22
1.8
22+22+25
1.72
22+22+35
1.5
22+22+50
1.26
22+25+25
1.64
22+25+35
1.45
22+25+50
1.23
22+35+35
1.3
25+25+25
1.8
25+25+35
1.59
25+25+50
1.35
25+35+35
1.42
Cooling capacity (kW)
Unit B
Unit C
–
–
–
–
–
–
–
–
2.2
–
2.5
–
3.32
–
3.75
–
2.5
–
3.15
–
3.6
–
2.7
–
3.18
–
2.7
–
1.8
1.8
1.72
1.96
1.5
2.4
1.26
2.88
1.88
1.88
1.65
2.3
1.39
2.78
2.05
2.05
1.8
1.8
1.59
2.22
1.35
2.7
1.99
1.99
NOTE: Electrical data is for outdoor unit only.
Outdoor unit
power consumption
Total
(kW)
2.2
0.590
(1.4 - 3.0)
(0.420 - 0.740)
2.5
0.660
(1.4 - 3.3)
(0.420 - 0.830)
3.5
0.950
(1.5 - 4.3)
(0.430 - 1.180)
5.0
1.500
(1.6 - 5.6)
(0.480 - 1.660)
4.4
1.180
(2.0 - 5.4)
(0.540 - 1.450)
4.7
1.300
(2.0 - 5.8)
(0.540 - 1.630)
5.4
1.600
(2.0 - 6.8)
(0.540 - 2.550)
5.4
1.580
(2.0 - 6.8)
(0.550 - 2.440)
5.0
1.420
(2.0 - 6.0)
(0.540 - 1.750)
5.4
1.600
(2.0 - 6.8)
(0.540 - 2.550)
5.4
1.580
(2.0 - 6.8)
(0.550 - 2.440)
5.4
1.600
(2.0 - 6.8)
(0.540 - 2.550)
5.4
1.530
(2.0 - 6.8)
(0.550 - 2.440)
5.4
1.550
(2.1 - 6.8)
(0.560 - 2.340)
5.4
1.295
(2.9 - 6.8)
(0.670 - 1.770)
5.4
1.295
(2.9 - 6.8)
(0.670 - 1.770)
5.4
1.295
(2.9 - 6.8)
(0.670 - 1.770)
5.4
1.265
(2.9 - 6.8)
(0.680 - 1.790)
5.4
1.295
(2.9 - 6.8)
(0.670 - 1.770)
5.4
1.295
(2.9 - 6.8)
(0.670 - 1.770)
5.4
1.265
(2.9 - 6.8)
(0.680 - 1.790)
5.4
1.295
(2.9 - 6.8)
(0.670 - 1.770)
5.4
1.295
(2.9 - 6.8)
(0.670 - 1.770)
5.4
1.295
(2.9 - 6.8)
(0.670 - 1.770)
5.4
1.265
(2.9 - 6.8)
(0.680 - 1.790)
5.4
1.295
(2.9 - 6.8)
(0.670 - 1.770)
Tabla de combinaciones
Current
(A)
2.59
2.90
4.17
6.59
5.18
5.71
7.03
6.94
6.24
7.03
6.94
7.03
6.72
6.81
5.69
5.69
5.69
5.56
5.69
5.69
5.56
5.69
5.69
5.69
5.56
5.69
Power
factor
(%)
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
379