Number of
data bytes to
be written
Recorded data
1
Recorded data
2
CRC code
Address Function code Start address Number of registers Total number
of data bytes Save data 1 Save data 2 CRC low 8 bits CRC high 8 bits
01 10 1000 0002 04 04E2 0226 1F D3
The format of the message sent back by the slave:
Slave device
response
Slave address
Function code
Start address
Number of
registers to be
written
CRC code
Slave address Function code Start address Number of registers CRC low
8 bits CRC high 8 bits
01 10 1000 0002 45 08
c)
Function code '06H': write to single register
This function is used to save a fragment of data in the PSU memory. For
instance, changing the voltage to 19.99V. After multiplying the value by
100 and converting it to hexadecimal format, it should be written to the
slave register with address 1000H (the slave address code is 01).
Format of the message sent by the host:
Message from
host
1
04
2
04E2 (12.50V)
2
0226 (5.5.A)
2
1FD3
Bit
Sent message
1
01
1
10
2
1000
2
0002
2
4508
Byte
Sent message
Total number of
data bytes stored (4
bytes)
Data to be written
to register 1000
Data to be written
to register 1001
CRC code calculated
by the host
Remarks
Information from the
device with address
01
Records of multiple
records
Starting address of the
register to be
recorded
Number of written
registers
CRC code calculated
by the slave
Remarks