Rinsing; Residual Hardness Setting; Operation; Salt Refill - BWT A6X Instrucciones De Montaje Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 66

SALT REFILL

The device uses regenerating salt, dedicated to softening. The salt tank bottom shall always be covered by solid salt over its whole surface. Please
refer to the Scope of Delivey sheet in order to know the salt storage capacity of your softener, and to the chapter TECHNICAL FEATURES to know its
salt consumption per regeneration.
Concerning the softeners with salt level follow-up by smartphone app:
After every salt refill, enter the salt level so that
the app may follow it up.
• Check the salt level once the refill is done, on
the scale inside the salt tank
• Press 5 seconds the è key to see LEVEL on
the display
• Select the salt level with ê and é keys
• Confirm with OK

AUTOMATIC DISPLAYED MESSAGES

The displays shows:
Œ an upper information line
 a lower information line
Ž a bargraph with 10 segments, showing the
remaining autonomy of the softener before the
next regeneration, by steps of 10%. The graph
in this example shows 70% remaining autonomy
For each operation step of the device, the dis-
played messages are as follows:
Ž


MANUAL REGENERATION

At any time, it is possible to trigger the rege-
neration of the softener, via the long press (5
seconds) on the OK key.
If this is done for a test purpose, it is possible to
manually go from one step to the next by briefly
pressing the OK key.

SALT ALARM ACKNOWLEDGEMENT

When no salt is left in the tank, the device
displays the alternate words SALT and CHECK.
Once the salt refill is done, you may just wait for
the next regeneration to let this alarm disappear.
It is recommended though to acknowledge
immediately the alarm, following these steps:
• Proceed with a long press (5 seconds) on the
M key
• Then briefly press this M key to go through
Accessed by the code 23, then the browsing works in the same way as the regular setting mode. The intervention on the advanced setting shall be
done by a trained professional. Any mistake can disturb the work of the device and is under its author's responsibility.
Step n°
Display
PASSW ?
0
Enter the password to go through the advanced setting.
00
1
Activation or not of the statistic volume
STATIS
PROP R
2
Enable / disable the proportional regeneration.
On
CAPA
Modify the softening capacity of the device, which has been automatically
3
80
set once the resin volume was selected (step 3 of regular setting).
Adjust the water consumption per full regeneration.
CONSU
4
Only for devices with the salt level follow-up by smartphone app.
71
Adjust the salt consumption per full regeneration.
SALT
5
Only for devices with the salt level follow-up by smartphone app.
2000
VOL OK
6
Volume of softened water (read only info). Here: 856 liters.
856
PEAKFL
Peak flow recorded since the last regeneration (read only info). Here:
7
1068
1068 liters per hour.
-14-

OPERATION

SERV
Alternate
with
REMPL
375
SAUM
180
REGE 1
00:45
REGE 2
18:35
REGE 3
02:15
Alternate
CHECK
with
Œ
STD-BY
Alternate
12:30
with
the menus until the display shows this one:
CHECK / SALT (alternate)
On
• Press once on ê or é key to make OFF appear
on the lower line
• Press OK to confirm
• Press M during 5 seconds to quit the menu:
the alarm shall disappear

POWER CUT

In case of a power cut during a regeneration, this
process restarts at the beginning of the ongoing
step. In case of a power cut during service, the
softener will restart also in service.

STAND-BY MODE

It is possible to prevent the softener from going
through a regeneration, automatic or manual.
This might be useful, for example, while you are

ADVANCED SETTING

Purpose
Code P0011144GR - Rev 16 - 04/01/2022
968
The device is in service: it delivers softened water.
Its treatment autonomy before regeneration is here 968 liters.
Water is being poured into the salt tank (see chapter AD-
VANCED SETTING), it will end in 375 seconds.
The brine is under preparation in the salt tank for the next
regeneration; this step will end here in 180 minutes.
The softener is going through its first active regeneration step,
which will end here in 0 minutes and 45 seconds.
The softener is going through its second active regeneration
step, which will end here in 18 minutes and 35 seconds.
The softener is going through its third active regeneration step,
which will end here in 02 minutes and 15 seconds.
The softener detects a lack of salt and advises to check the salt
SALT
level in the salt tank.
The regeneration function is OFF (see Stand-By mode next
968
page). The softener delivers soft water as long as its autonomy
12:30
allows it (here: autonomy of 968 liters).
waiting for the intervention of a technician in
case of technical problem. Therefore:
• Proceed with a long press (5 seconds) on the
M key
• Then briefly press this M key to go through
the menus until the display shows this one:
• Press once on ê or é key to make ON dis-
played on the lower line
• Press OK to confirm
The display shows then the message STD-BY
alternating with the softener autonomy value.
To cancel this function, you just have to come
back to this STAND-BY menu and turn the lower
line into OFF.
êé to change
OK to confirm
çM to cancel
êé to change
OK to confirm
çM to cancel
ê to turn on / off
OK to confirm
çM to cancel
êé to change
OK to confirm
çM to cancel
êé to change
OK to confirm
çM to cancel
êé to change
OK to confirm
çM to cancel
çM to go to next step
çM to go to next step
STD-BY
Off
Action

Publicidad

Tabla de contenido
loading

Tabla de contenido