WARNING:
Always shut off engine before fueling. Never remove
fuel cap or add fuel to a machine with a running or hot
engine. Make sure the unit is sitting on a flat, level surface
and only add fuel outdoors. If the engine is hot, let the
unit cool for at least five minutes before adding fuel.
After fueling, immediately replace fuel cap and tighten
securely. Move at least 30 ft. from refueling site before
starting engine. Do not smoke and stay away from open
flames and sparks! Failure to follow these instructions
could result in a fire and cause serious personal injury.
NOTE: Always use unleaded gasoline with a pump octane
rating of 86 or higher. Never use old, stale, or contaminated
gasoline, and do not use an oil/gas mixture. Do not allow dirt
or water into the fuel tank. Do not use E85 fuel.
STARTING THE ENGINE
See Figures 5 - 8.
NOTICE:
On a level surface with the engine off, check the lubricant
level before each use of the generator.
NOTICE:
Do not place the generator directly on the ground when
using the unit in grassy areas or in areas with dense
vegetation. Doing so could result in grass discoloration
and/or localized soil damage.
NOTE: If location of generator is not level, the unit may not
start or may shut down during operation.
Unplug all loads from the generator.
Put the on/off switch/fuel valve in the ON ( I ) position.
NOTE: When the on/off switch/fuel valve is in the ON (I)
position fuel will flow from the fuel tank to the engine.
Move the choke lever right to the START position.
NOTE: If engine is warm, move the choke lever left to
the RUN position.
Put the auto idle switch in the OFF (O) position.
Pull the starter grip and rope until the engine runs.
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place.
Allow the engine to run for 15 - 30 seconds, then move
the choke lever left to the RUN position.
NOTE: For quieter more efficient operation, place the
auto idle switch in the ON (I) position.
OPERATION
STOPPING THE ENGINE
See Figure 5.
Remove any load from the generator.
Put the on/off switch/fuel valve in the OFF ( O ) position.
To stop the engine in an emergency situation:
Put the on/off switch/fuel valve in the OFF ( O ) position.
WARNING:
While operating and storing, keep at least 3 feet of
clearance on all sides of this product, including overhead.
Allow a minimum of 30 minutes of "cool down" time
before storage. Heat created by muffler and exhaust
gases could be hot enough to cause serious burns and/
or ignite combustible objects.
USING THE BATTERY CHARGING CABLE
See Figure 9.
WARNING:
The 12V DC receptacle is designed to charge vented wet
lead acid batteries only. Other types of batteries could
burst, causing personal injury and damage.
NOTICE:
The 12 V DC receptacle provides continuous charge. Do
not overcharge battery or leave battery unattended. Doing
so may cause damage to the battery.
NOTICE:
Do not use the generator to jump start vehicles. Doing
so could result in damage to the vehicle or it's electrical
components.
Place the auto idle switch in the OFF (O) position.
Using the battery clamps, connect the battery charging
cable assembly to the battery terminal. Connect the red
wire to the positive (+) terminal first, then connect the
black wire to the negative (–) terminal. Make sure all con-
nections are secure.
NOTE: Be careful not to short across the terminals when
installing. Shorting the terminals together can cause
sparks, damage to the battery or generator, or even burns
or explosions.
NOTE: To prevent short circuit, keep away from a metal
surface during clamp connection.