Function; Display Elements; Part Label - Balluff BTL PF Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL PF Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 101
BTL PF _ 400- _ _ _ _ -C15A _ _ _ _ - _ _ _ _ _ _
Magnetostrictive Linear Position Sensor – Profile Style
4
Product description (continued)
4.2

Function

To determine the position of a plant component, a magnet
is connected to the component. Together they are moved
along a waveguide located inside the BTL.
An internally generated INIT pulse interacts with the
magnetic field of the magnet to generate a torsional wave
in the waveguide which propagates at ultrasonic velocity.
The component of the torsional wave which arrives at the
end of the waveguide is absorbed in the damping zone to
prevent reflection. The component of the torsional wave
which arrives at the beginning of the waveguide is
converted by a coil into an electrical signal. The position of
the magnet and thus at the same time that of the plant
component is determined from the running time of the
shaft.
Depending on the version, the position is output as a
voltage or current value with rising or falling gradient.
Up to 2 magnets can be used for FMM (Flexible Magnet
Mode).
The following functions can be selected for the output
values:
Position
Velocity
Position difference
The entire range of functions can only be
configured with the PC software B
(BET). For this, the IO-Link
E
T
nginEEring
ool
master must be connected. Communication is
realized via IO-Link.
www.balluff.com
4.3
Signal
Green
Yellow
flashing, 3 Hz
Red flashing,
1 Hz
Red flashing,
3 Hz
1)
Is only displayed for versions with 2 current outputs if the error is present
at the same time at both outputs.
Tab. 4-1:
With 1 magnet and 2 outputs the priority of the LED
display is as follows (highest to lowest priority):
Output error
Measurement error
Warning
Normal function
For FMM (Flexible Magnet Mode) with 1 magnet the LED
display relates to output 1 (output 2 issues the error value
continuously).
alluff
For FMM (Flexible Magnet Mode) with 2 magnets the LED
display shows the status with the highest priority of both
outputs.
More than 2 magnets are ignored.
4.4
Order code
2)
3)
Type
Serial number
4)
Fig. 4-2:

Display elements

Meaning
Normal function
Magnet is within the measuring range.
Warning
Magnet is outside the measuring range.
Measurement error
No magnet
Output error
1)
Short-circuit at voltage output or
interruption on current output.
LED display

Part label

2)
4)
Part label (section, example)
english
3)
4)
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Btl pf1400-0500-c15aa1c0-000s15

Tabla de contenido