Pipe Patch
Figure 8 – Marking Patch Position On Camera Push Rod,
Transferring To Air Push Rod or Air Hose
10
10
Lock each pushrod coupling (Figure 9) to reduce the
risk that they come apart in the drain. Wrap each
locked coupling with tape from one red section to the
next to prevent resin from entering and curing in the
coupling.
The 2" Packer has an integral push hose and it
cannot be used with separate air push rods.
a. Loosen Locking Ring on Female Fitting
Hex
b. Align the Fittings and Push Together
c. Tighten the Locking Ring
d. Sleeve Tightened
e. Tape the Connection
Figure 9 – Locking Air Push Rod Couplings
Pull Ropes
A pull rope connection point is supplied at both ends
of the packer. A pull rope is always used at the air
supply end of the packer to withdraw the packer (do
not pull on the air push rod or air hose unless you are
using the 2" packer).
Locking Ring
999-995-411.10_REV A