Weighing With Preset Tare Values; Hold Function; Bmi Function - Soehnle Professional 6831 Instrucciones De Manejo

Ocultar thumbs Ver también para 6831:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

6. Operations

6.4 Weighing with preset tare values

Press [ON/OFF/ZERO] with no load on the scale.
f
Press and hold the [TARE/PRESET] key until the NET indicator flashes and
f
"Pr.Tare" shows up in the display.
Input the tare weight using the arrow keys
f
(already known the weight of the wheelchair).
After inputting the tare weight, press the [TARE/PRESET] key to confirm.
f
The NET indicator will be lit on the display.
Note: Tare weight must be greater than zero and less than the scale's
maximum capacity.
Put the patient and the additional weight (e.g. in the wheelchair) to be
f
weighed onto the scale platform. The net weight will be displayed.
To exit preset tare mode, remove all weight from the scale. The display will
f
show a negative weight. Press the [TARE/PRESET] key to return the display
to zero, eliminating the weight of the container.
Note: The indicator can only save one tare weight. Entering a new tare
weight will automatically replace the old one.

6.5 Hold function

The Hold function is being used if you like to hold the results at the display after
the weight/load has been removed from the scale. Use this button to take care of
the patient first and then note the weight.
Press [HOLD/SETUP] while scale is under load.
f
"HOLD" is being displayed at the screen.
f
The weight remains saved in the display after unloading the scale.
f
For deactivation of the Hold function press again the HOLD/SETUP key.
f
26
6. Operations

6.6 BMI function

The Body Mass Index is the ratio between body height and weight squared. The
BMI is helping to evaluate the state of nutrition and with that value also the state
of health of a person. The result is a tolerance value.
Start the scale by entering the [ON/OFF/ZERO] button. The scale is
f
automatically being set to zero.
Step on the scale or helping the patient to get into the wheelchair and on the
f
platform
Wait until the weight is being displayed in a stable condition and
f
on the screen.
Press the BMI key shortly.
f
The scale starts automatically with the last input. Use the [Arrow] buttons to
f
enter the height of the patient, and confirm the height with the [Enter] button
The BMI is now being displayed at the indicator.
f
To correct the given height press the [BMI] button once again and the display
f
returns to the height mode.
To get back into normal weighing mode and leave the BMI modus, press the
f
[TARE] button.
Evaluation of the Body Mass Index
Compare the determined value which corresponds to those being used by the WHO.
BMI below 18,5
The patient is under the regular standard and does not got enough weight. An
increase of weight is recommended. Please consult a professional.
BMI between 18,5 and 24,9
The patient got a normal weight. If he feels well there is no need for a change.
BMI between 25 and 30
The patient is slightly overweighed to pre-obese. A reduction of weight is
indicated or, is necessary if the state of health is already affected (e.g. diabetes,
high end blood pressure, heart diseases).
BMI over 30
Reduction of weight is imperative. To visit a doctor is highly recommended.
appears
27