Fig.4
Fig.5
In order to correct any initial programming errors,
during the execution of the COFFEE SLUSH
cycle it is always possible to vary the time setting
via the following procedure:
-
With the cycle in progress, press the STOP and
AUTOMATICO (AUTOMATIC) keys again (Fig.
4).
-
The
LEDs
of
(CONFIRM) (◄►) and DOWN (▼) keys light up
and
the numbers relative to the previously
configured time setting appear on the display.
Press the UP (▲) and DOWN (▼) keys to
correct the value.
-
Press the CONFERMA (CONFIRM) key (◄►) to
validate the new data and exit programming (Fig.
5).
the
UP
(▲),CONFERMA
ENGLISH - 22