All the disassembled parts must remain soaking in the Ecolab P3 Topax-san sanitizer
(4% dilution) for at least 15' before they are rinsed with plenty of cold drinking water.
• Rest the door on a clean work surface and
disassemble its parts:
1. Remove the plastic lid from the hopper.
2. Unscrew and remove the plastic knob.
3. Remove the steel slider, which controls the
dispenser disk, from the guides.
4. Remove the spring.
5. Remove the dispenser disk.
6. Use the OR disassembly device to remove the 2
OR gaskets from their place.
• Immerse the previously disassembled components
into the tub with the sanitising solution and brush the
surfaces with care. Pay special attention to the safety
grid and gaskets.
REMOVING AND CLEANING STIRRER
• Pull the beater towards you to remove it from the
batch freezing cylinder.
• Recover the seal gasket placed on the back of the
beater.
• Remove the scrapers from the beater by pressing
firmly on the small fixing tooth.
• Remove the metallic springs from the scrapers.
• Immerse the previously disassembled components
into the tub with the sanitising solution and brush the
surfaces with care. Pay special attention to the seats
of the scrapers and metallic springs.
ENGLISH - 26