ENTER THE TOSHIBA INVERTER STEPS : (ONLY PEB 30 230/50/1
VERSION)
Press MODE until the code AUH appears
Turn ROTARY to scroll the steps
Press ROTARY to enter the value
Turn ROTARY to modify the value
Press ROTARY to enter the value
To quit: press 3 times MODE
PROGRAMMING CHART OF THE TOSHIBA INVERTER
PARAMETERS
FUNCTION
SEt
Starting SETUP region
CMOd
RUN Command
FMOd
Frequeancy command
ACC
Acceleration time 1
dEC
Deceleration time 1
FH
Maximun frequency
UL
Max. frequency limit
LL
Min. frequency limit
uL
Base frequency 1 Nom.
uLu
Base voltage 1
Pt
Control mode V/F
F400
Motor auto-tuning
F405
Motor Power (kw)
F415
Motor current (A)
F417
Motor speed (RPM)
F701
Indication unit (A)
F800
Baud –Rate (38400 bps)
F801
Parity (1)
F802
Number inverter (1)
F829
Protocol (Modbus RTU)
The parameters may vary depending on the software version or customisation. You
(**)
can always refer to the test inspection board supplied with the machine.
29 - ENGLISH
PEB 30 230/50/1
SET
EU
2
3
6
1
100
100
10
50
230
2
2
0,18
1,2
1330
1
5
0
1
1