Descargar Imprimir esta página

Sime MURELLE HE 35 R ErP Manual De Instrucciones página 102

Ocultar thumbs Ver también para MURELLE HE 35 R ErP:

Publicidad

Idiomas disponibles

Idiomas disponibles

7
9...Visualizzazione.numero.giri.ventilatore.in.rpm.x.100.(es..4.800.e.1.850.rpm)
4 
USE AND MAINTENANCE
ATTENTION: Before performing any work on the boiler, make sure that the same and its components have 
cooled in order to prevent the risk of burns due to high temperatures.
10...Visualizzazione.ore.di.funzionamento.del.bruciatore.in.h.x.100.(es..14.000.e.10)
4.2 
GAS CONVERSION (fig. 17)
This  operation  must  be  performed  by 
authorised personnel using original Sime 
11...Visualizzazione.numero.di.accensioni.del.bruciatore.x.1.000.(es..97.000.e.500)
12...Visualizzazione.codice.errore
.......ultima.anomalia
4
3
2
13...Visualizzazione.codice.errore
.......penultima.anomalia
1
14...Visualizzazione.numero.totale
.......delle.anomalie
KEY
1.
Upstream.pressure.intake
2.
Intermediate.pressure.intake
3.
Air.signal.inlet.(VENT)
4.
Downstream.pressure.intake
5.
Shutter
6.
OFF-SET
15...Contatore.accessi.parametri
.......installatore.(es..140.accessi)
16...Contatore.accessi.parametri
components.
.......OEM.(es..48.accessi)
To.convert.from.natural.gas.to.LPG.or.vice.
versa,.perform.the.following.operations
–.Close.the.gas.cock.
–.Replace.the.two.differential.nozzles.(1-2).
and. relative. seal. o-rings. (3). with. those.
supplied. in. the. transformation. kit.. The.
difference.in.the.shape.of.the.head.of.the.
nozzles,.avoid.reversal.during.assembly.
–.Apply. the. nameplate. with. the. new. gas.
flow.layout.
–.Calibrate. the. maximum. and. minimum.
pressures. of. the. gas. valve. following. the.
instructions.provided.in.paragraph.4.2.2.
4.2.1 
New fuel configuration
5
5
For. access. to. the. installer's. parameters,.
press.simultaneously.keys.
5.seconds.(3.fig..12)..
The. parameters. will. scroll. up. and. down.
with.the.keys
.and.
The.display.pane.will.show.the.values.of.the.
1
1
parameter.PAR.1..
If.the.boiler.is.a.methane.(G20).model,.SET.
3.will.be.displayed:
2
2
4
102
5
6
T o.
5
change. the. fuel. to. propane. (G31),. it. is.
necessary. to. set. SET. 11,. by. pressing. the.
key.
Fig..16
1
2
The. standard. display. will. automatically.
return.after.10.seconds..
The.table.below.shows.the.SET.settings.to.
enter.when.the.type.of.gas.fuel.is.changed.
.
.
.
METHANE.
.
.
5
.
5
.
.
.
3
3
.
.
.
.and
for.
. .PROPANE.
.
1
1
3
.
3
..
.
.
2
2
4.2.2 
4
4
Measure.the.CO
4
analyzer.
B
4
3
.
4
GAS  
MODEL 
PAR 1
.
.
Single.(35.R.ErP).
(G.20).
.
Sequence/cascade..
.
..
.
Single.(35.R.ErP).
(G.31).
.
Sequence/cascade..
.
.
Calibrating the gas valve 
pressures
.values.with.a.combustion.
2
5
3
6
1
2
3
5
Sequence of operations:
1). Press. and. hold. the. button. down. for. a.
.
few.seconds.
1
2). Press.the.button.for.a.few.seconds
3). Identify.the.CO
.values.at.max..power.by.
2
adjusting.the.shutter.(5.fig..16):
2
   
                MAX power
CO
 (Methane) 
2
.
9,3.±0,2.
4). Press.the.button.for.a.few.seconds.
5). Identify.the.CO
.values.at.min..power.by.
2
adjusting.the.OFF-SET.regulation.screw.
(6.fig..16):
                MIN power
5
CO
 (Methane) 
2
.
8,4.±0,2.
6). Press. the. buttons. several. times. to.
5
check.the.pressures.
ge.them.if.required.
3
1
7). Press.the.button.
4
the.function.
1
2
4.4 
DISASSEMBLING 
11
   
THE SHELL (fig. 19)
2
To.simplify.maintenance.operations.on.the.
boiler,. it. is. also. possible. to. completely.
12
remove.the.shell,.as.shown.in.figure.19..
Turn. the. control. panel. to. move. it. forward.
and.be.able.to.access.the.internal.compo-
nents.of.the.boiler.
4.5 
MAINTENANCE (fig. 20)
To. guarantee. functioning. and. efficiency. of.
Fig..17
5
3
3
.
1
5
2
4
 CO
 (Propane)
2
10,2.±0,3
4
3
.
1
2
5
 CO
 (Propane)
2
4
10,0.±0,3
3
3
.
.
and.
chan-
1
3
. once.more.to.quit.
2
4
4
4

Publicidad

loading