Codice/Code 8113370
Modello/Model MURELLE HE 35 R ErP
Matricola/Serial n. 9999999999
PAR 1 = 3 (G20) / 11 (G31)
PAR 2 = 5
the. appliance,. in. respect. of. the. legal. pro-
visions. in. force,. it. must. be. regularly. che-
cked;.the.frequency.of.the.checks.depends.
on.the.type.of.appliance.and.the.installation.
and.usage.conditions.
In.any.case,.it.should.be.inspected.at.least.
once.a.year.by.a.qualified.technician.
During maintenance operations, it is
important to verify that the drip-plate
with drain trap contains water (this check
is particularly important if the generator
has not been used for extended periods
of time).
ATTENTION
Before removing or refitting the front
panel of the boiler, open the small
upper plastic door.
If necessary, the drip plate can be filled
using the tap provided (fig. 20).
5
4.5.1
Chimney sweep function (fig. 21)
To. check. boiler. combustion,. press. the.
3
installer's.
key.
for. a. few.
seconds..
.
chimney.sweep.function.will.switch.on.and.
1
will.continue.for.15.minutes.
From. that. moment,. the. boiler. will. start.
working. in. heating. mode. at. maximum.
power,.with.cut.off.at.80°C.and.re-ignition.
2
at. 70°C. (ATTENTION! Temperature may
4
The.
ES
PT
ENG
Fig..19
Fig..20