Descargar Imprimir esta página

Sime MURELLE HE 35 R ErP Manual De Instrucciones página 99

Ocultar thumbs Ver también para MURELLE HE 35 R ErP:

Publicidad

Idiomas disponibles

Idiomas disponibles

BOILER 
.
Instant.with.deviator.valve..
.
and.flowmeter
.
.
Instant.with.deviator.valve,..
.flowmeter.and.solar.combination
.
D.H.W..tank.with.
.deviator.valve.and.boiler.sensor..
.
vers..T.(LOW.INERTIA).
.
On.board.D.H.W..tank.with
.deviator.valve.and.D.H.W..sensor...
.
(LOW.INERTIA).
. R emote.D.H.W..tank.with.deviator.
. valve.and.D.H.W..thermostat...
.
or.heating.only.vers..T/R.boiler
.
(LOW.INERTIA)
.
On.board.D.H.W..tank.with
.double.pump.and.D.H.W..sensor...
.
vers..T/R.boiler.
.
(LOW.INERTIA)
.
On.board.D.H.W..tank.with
.
double.pump.and.D.H.W..
. thermostat.vers..T/R.boiler...
.
(LOW.INERTIA).
.
Heating.only.with
.
antifreeze.sensor...
.
(LOW.INERTIA)
NOTE:  the  inside  of  the  upper  door  of 
the  boiler  panel  has  a  label  with  the 
values that have to be set for PAR 1 and 
PAR 2 (fig. 19). 
5
3.3.2 
Warning
Should. the. boiler. operation. not. be. opti-
mal. but. no. alarm. sets. off,. press. the.
3
button..
.until.info.70.and.the.warning.
code.associated.to.the.ongoing.event.are.
1
displayed.
Once. optimal. operation. is. restored,. info.
70.will.display:."-.-".
Below.is.the.table.of.warning.codes:.
2
 CODE 
DESCRIPTION
4
. E0.
Reduced.capacity.operation.
.
.
(∆t.between.delivery.and.return.
.
.
over.40°C)
. E1.
Shorted.external.sensor.(SE)
  E2.
Preheating.function.active
. E3.
TBD
. E4.
TBD
. E5.
TBD
. E6.
TBD
. E7.
TBD
. E8.
TBD
. E9.
TBD
PAR 2
1
EXPANSION CARD
2
PAR.DESCRIPTION...
.
.
40.
Number.of.expansion.boards..
3
41.
Mix.valve.stroke.time.
42.
Priority.of.D.H.W..over.mixed.zone.
.
.
43.
Floor.drying.
4
.
.
.
.
.
.
5
44.
Type.of.solar.system.
45.
t.solar.collector.pump.1.
46.
Solar.integration.delay..
47.
Tmin.solar.collector.
48.
Tmax.solar.collector.
6
PARAMETERS RESTORATION 
PAR.DESCRIPTION...
8
.
.
49.*. Reset.default.parameters.
.
(par.01.-.par.02.=.."-")
9
*   In case of difficulty in understanding the current setting or in case of an anomalous or 
  incomprehensible conduct of the boiler, we suggest to restore the initial values of the parameters 
  setting PAR 49 = 1 and the  PAR 1 and PAR 2 as specified at point 3.3.1.  
When the appliance is installed in sequence/cascade (modular 
system with several generators) it is necessary to set on all the 
boilers the following INST PAR parameters:
PAR 1    =  
PAR 15  =  
5
5
In addition, when the number of boilers in cascade is more than 
two, configure the parameters OEM A1 of the MASTER boiler.
To access the OEM parameters press simultaneously the but-
tons (
 and 
press  simultaneously  he  buttons  (
1
1
seconds.  At  this  point  insert  the  access  code  formed  by  this 
sequence of INSTALLATOR BUTTONS: 
" + / - / < / > / < ".  
2
2
Set the parameter:
PAR A1   =    Number of cascade generators (3 ... 8)
PARAMETERS INSTALLER
RANGE.
.
0.....3.
0.....199.
0.=.Paralle.
1.=.Absolute
0.=.No.activated.
1.=.Curve.A
2.=.Curve.B
3.=.Curve.A+B
1.....8.
PAR.74.OEM.-.1....50.
"--",.0.....199.
"--",.-30.....0.
"--",.80.....199.
RANGE.
.
--.,.1.
CASCADE CONNECTION PARAMETERS
4 (for NATURAL GAS boilers)
12 (for PROPANE boilers)
0 for the first boiler (MASTER)
1 .... 7 for the other boilers (SLAVE)
(Avoid assigning the same number to SLAVE boi-
lers)
5
3
3
) for 2 seconds. Entered in the INST level again 
1
2
4
4
UNIT.OF.
INC/DEC..
DEFAULT
MEASUREMENT.
UNIT.
SETTING
=.
1.
10.sec..
1.
=.
=.
=.
=.
=.
1.
°C.
1.
Min..
1.
°C.
1.
-.10
°C.
1.
UNIT.OF.
INC/DEC..
DEFAULT
MEASUREMENT.
UNIT.
SETTING
=.
=.
5
3
3
  and 
)  for  another  2 
1
2
4
4
ES
PT
ENG
0
12
1
0
1
8
0
120
=
99

Publicidad