INSTALLATION
INSTALL ELECTRICAL JUNCTION BOX
(NOT INCLUDED)
See Figure 10.
l Ensure that the main circuit breaker in the load center is
in the OFF position.
l Mount the junction box within six inches of the transfer
switch on the side farthest from the load center.
l Pull the small bundle of wires through the opening in the
transfer switch closest to the junction box and connect it
to the junction box.
NOTE: Use appropriate conduits and fittings to secure
the wire bundle.
WARNING
front bottom cover and all other openings are
properly reinstalled, covered, or sealed to prevent
electrical components from being exposed.
FIG. 9
FIG. 10
A - Junction Box (Not Included)
After installation, ensure the
A
MOUNTING THE POWER INLET BOX
See Figures 11 - 14.
Mount the power inlet box outdoors at least 5 feet away
from doors, windows, air conditioning units, and vents
so portable generators can be connected and operated
safely.
l Ensure that the main circuit breaker in the load center is
in the OFF position.
l Select a suitable location for the power inlet box along
an outside wall.
l Remove the screws in the front of the power inlet box.
l Separate the front cover, receptacle, and back cover.
l Place the back cover against the outside wall and mark
hole locations including the center hole.
l Predrill three holes for the screws and use a hole saw to
create an opening in the center hole position.
FIG. 11
B
A - Back Cover
B - Front Cover
C - Screw
D - Receptacle
FIG. 12
A
B
A - Back Cover
B - Screw
A
D
C
English | 11