6.3.
Display screens after switching on
6.3.1.
Display screens after switching on
Step
Display
8.8.8.8.
1
F 6.0 3
2
t C.S
3
20
4
5
6.3.2.
Display in firing mode
Display
.
4 1 1
6.3.3.
Segment display
Display screen Segment
° C
° F
Icon
Description
After switching on, the controller carries out a display test.
All indicators light up.
The controller will sound a short beep.
The controller displays the version number of the integrated software.
When contacting technical customer support, you will need:
The thermocouple type setting is now displayed.
This should match the type of thermocouple fitted to the kiln and can be
R, S, K or N.
The final display shows the kiln temperature.
No other illuminated elements should not light up during this time.
If any graphical display LEDs are on, then the control unit is firing.
The firing process can be stopped with the
Icon
Description
During firing, the illuminated (decimal) point to the right of the temperature ("411")
in the display shows that the kiln is heating up.
Description
When the controller is switched on, the segment display shows the possible
temperature units during operation (°C/°F).
The temperature units can be configured as parameters (see Section 12.).
the version number
the serial number of the device
51 / 291 - EN -
j
key.