7.4.
Event programming (ST 411 only)
When programming a ramp or a soak period – while programming a firing program – the switch output can also be
selected for the respective program step by pressing the switch output (event) key.
7.4.1.
Event programming
Main display
Heating or cooling ramp
150
Soak time
00. 15
7.4.2.
Switch outputs (event) indicator
Switch output
Switch output
Event 1 ON
Event OFF
Note:
Before the program runs, the switch output (event) is inactive (relay contacts are open).
Meaning
Switch output indicator
Heating ramp
Cooling ramp
Soak time
Description
indicator
The indicator LED for the switch output (event ) lights up (relay contacts are
closed).
The indicator LEDs for the switch output do not light up (relay contacts are
open).
Description
Event 1:
While programming a ramp, press
the
Event 1:
While programming a soak time, press
the
59 / 291 - EN -
*
key to select event 1.
*
key to select event 1.