Descargar Imprimir esta página

Airless DERBY 270 Instrucciones De Uso página 35

Publicidad

TYPE
E00
No gas
E01
cover open during cycle
E02
the cover does not open after air return
E03
cover remains closed when machine powered on
.
E08
change oil
E09
fatal error
EF
motor phase inverted
DESCRIPTION
35
FAULT SIGNALS
check:
- the gas pipe is connected to the machine,
- the gas tap on the cylinder is open,
- the outlet pressure is between 1.0 and 1.5 bar.
PRESS KEY (O) TO RESET THE ERROR.
- gas injection time too high,
- cover seal faulty.
PRESS KEY (O) TO RESET THE ERROR
check:
- the gas springs are not released,
- the AIR RETURN EV is not faulty,
- the pneumatic circuit is correctly connected,
- the electrical circuit is correctly connected
PRESS KEY (O) TO RESET THE ERROR.
check:
- the gas springs are not released,
- power is available during the vacuum cycle.
PRESS KEY (O) TO RESET THE ERROR.
change the pump oil as instructed in the attached booklet.
PRESS KEY (O) TO RESET THE ALARM and run a new vacuum cycle.
CONTACT CUSTOMER ASSISTANCE TO RESET THE OIL CHANGE.
switch off the machine promptly and contact technical support.
invert two phases in the plug
SOLUTION
SVT18-010AR rev 00-15-05-18