The A510034 and A510035 control units may be connected to motors with either
mechanical or electronic limit switches. Depending on the type of motor connected, the
control unit will have two operational modes:
SMART MODE
Motors with mechanical limit switches
(motors with standard wiring).
The control unit is able to recognise
motor movements and thereby process its
functions faster and more precisely.
Types of tilt mechanism managed:
- 2 positions
- 3 positions "CH White"
- 3 positions "CH Black"
--> See from page 42 to page 51
SMART MODE - motors with mechanical limit switches
ADJUSTMENT OF THE LIMIT SWITCHES
Before connecting the control unit adjust the mechanical limit
ADJUSTMENT OF THE LIMIT SWITCHES
Use the motor adjustment screws to bring the blind to the desired position (refer to the
motor instruction booklet).
After adjustment of the limit switches connect the control unit.
OPERATIONAL MODES
Motors with electronic or mechanical limit
switches (motors with standard wiring).
The control unit activates the UP and
DOWN commands for a predetermined
time (time-out).
Types of tilt mechanism managed:
- 2 positions
--> See from page 52 to page 57
switches on the motor.
42
TIMED MODE