TIMED MODE - motors with mechanical or electronic limit switches
Time-out is the time during which the control unit is active, that's to say an opening or
closing order is given. This time must always be longer than the opening-closing time of
the device blind controlled. The time-out ends after pressing the STOP button or also after
the setting value.
+
B
C
From factory setting: 90 seconds.
The control unit will keep this setting
even after complete memory clearing!
SETTING THE SLAT OPENING POSITION
The control unit has a pre-memorized open-slat position, of about 0,8 s, which enables
the automatic opening of the slats at an angle of between 30 and 45 degrees.
If one likes, it is possible to: • Change the slat opening position.
TIME-OUT SETTING
A
• Disable slat opening, so that the motor does not respond
to the brief STOP command.
54
A
180 s
B
90 s
C
45 s
2 sec