TIMED MODE - motors with mechanical or electronic limit switches
OPERATION AND CHECK OF MOTOR ROTATION DIRECTION
After having memorized the first remote control and enabled timed management of the
outputs, the control unit is ready for operation.
Press buttons A (UP) and C (DOWN) to check the proper association with the motor
rotation direction. If the association with the direction is not correct, (e.g. pressing A the
blind descends) do the following:
1) Delete the remote control
+
A
B
2) Memorize the remote control again
+
A
B
3) After the last confirmation movement the motor performs three (3) long movements of
10 seconds each (Up/Down/Up or Down/Up/Down). During the movement press the button
corresponding to the movement performed by the blind (A for ascent, C for descent).
?
A
B
A
C
T1 (1 sec)
53
B
B
The motor stops: the UP and
DOWN buttons are now
properly associated.