9.2 Technical data
Acoustic pressure level A in distance of
Max. permissible ambient temperature: +5 °C to 40 °C
Max. permissible air rel. humidity: 85 %
Notice: Observe also the data specified in the nameplate.
Serial No.: 1502206
Technical modifications without previous notification and errors reserved.
KEMPER CleanAirTower Instruction manual - EN
, serial No. 39 0600
CleanAirTower
Ventilator type: radial, with direct drive
Max. volume flow rate: 6,000 m³/h
Max. static pressure: 2,300 Pa
Motor output. 5.5 KW
Supply voltage: 3 x 400 V
Frequency: 50 Hz
Nominal current: 11.0 A
Switching on time: 100 %
Control voltage: 24 V / DC
Filter area: 58 m²
Level of separation: ≥ 99,9 %
Filter material: PTFE membrane filter
Dust class: "M" according to DIN EN 60335-2-69
Method of cleaning: Cleaning by pressure impact
Required air pressure: 5 – 6 bar, clean and dry air free of oil
Total height: 3,545 mm
Total weight: 653 kg
Ventilator unit
Weight: 328 kg
Dimensions: max. Ø = 1,172 mm
Filtration unit
Weight: 185 kg
Dimensions: max. Ø = 1,070 mm
Suction section
Weight: 140 kg
Dimensions: max. Ø = 1,070 mm
L
< 72 dB(A)
pa
1 m:
height = 1,463 mm
height = 1,425 mm
height = 657 mm
- 82 -
Rev.:
1
Status as of: 05/2014