Keep away children from acid
and batteries!
Risk of explosion!
Fire, sparks, open light, and
smoking not allowed!
Danger of causticization!
First aid!
Warning note!
Disposal!
Do not throw the battery in the
dustbin!
Danger
Risk of explosion! Do not put tools or similar
on the battery, i.e. on the terminal poles
and cell connectors.
Danger
Risk of injury! Ensure that wounds never come
into contact with lead. Always clean your
hands after having worked with batteries.
Installing and connecting the battery
Insert battery in battery container.
Connect pole terminal (red cable) to
positive pole (+).
Connect pole terminal to negative pole
(-).
26
Close the battery container using the
cover.
Fasten the cover of the battery contain-
er with the fastening tape.
Note: Check that the battery pole and pole
terminals are adequately protected with
pole grease.
Charging battery
Danger
Risk of injury! Comply with safety regula-
tions on the handling of batteries. Observe
the directions provided by the manufacturer
of the charger.
Disconnect battery.
Connect positive terminal cable from
the charger to the positive pole connec-
tion on the battery.
Connect negative terminal cable from
the charger to the negative pole con-
nection on the battery.
Plug in mains connector and switch on
charger.
Charge battery using lowest possible
level of charging current.
Remove the battery
Loosen the tension strap of the battery
compartment lid.
Remove the lid of the battery compart-
ment.
Disconnect pole terminal to negative
pole (-).
Disconnect pole terminal to positive
pole (-).
Remove the battery from the battery
compartment.
Dispose of the used battery according
to the local provisions.
Check fluid level in the battery and ad-
just if required
Caution
Regularly check the fluid level in acid-filled
batteries.
Unscrew all cell caps.
Where fluid level is too low, top up cells
to the mark provided with distilled wa-
ter.
– 6
EN