Float Control Configuration
Float Setup
NOTE: No more than 2 floats can be configured to be used in the system during Auto mode.
1.
From the Home screen, select the Settings icon.
•
Refer to
"Home Screen Navigation" on page
2. Press the Sensors icon on the Settings screen.
3. Set each float switch type as Normally Open or Normally Closed.
4. Press OK in the pop-up menu to confirm selection.
Auto Mode Float Configuration
1.
Press Auto Mode Setup.
2. Set Pumping Behavior: refer to
•
Empty: to empty or draw down the location where the floats are installed.
•
Fill: to fill the location where the floats are installed.
3. Set Control Sensor as Float(s).
4. Set Monitoring Behavior as Maintain Level.
5. For Float Configuration, choose Single Float or Dual Float depending on the number of floats needed.
6. To start the system, refer to
Transducer Application Setup
1.
Plug in a level transducer to Analog 1 on the sensor input panel.
2. From the Home screen, press Settings.
3. If not already completed, press the Motor Settings button to set up the motor.
•
Refer to
"Motor Configuration" on page
•
Press Back when finished.
4. Press the Sensors button.
3
11.
"Auto Mode Settings Screen Navigation" on page
"Float Control Application Startup" on page
13.
DRIVE CONFIGURATION
Float Control Configuration
16.
25.
2
17