Float Control Application Startup
NOTE: Attempting to navigate away from the Auto Mode screen while the pump is in operation will cause a
warning screen to appear. Refer to
NOTE: Float switch(es) on/off status is indicated by the illustration on the screen, but does not accu-
rately portray installation depths.
1.
If not already complete, set up and configure the float(s).
Refer to
"Float Control Configuration" on page
2. Return to Auto Mode screen.
3. Use the door mounted dial to adjust the Float Speed.
This is the speed the pump will run when the floats call for a run command.
IMPORTANT: Motor rotation will start in the next step.
4. Press ENABLE button.
When the floats are activated to call for a run command, the pump will start.
5. Monitor the rotation of the motor fan and shaft coupling.
6. If rotation is incorrect, press FWD/REV and confirm the selection in the pop-up dialog box.
The pump will slow to a stop, change direction, and restart automatically.
7.
Adjust speed as required using the door mounted dial.
Motor speed will be displayed on the RPM Gauge.
8. Press DISABLE to turn off the pump and deactivate auto mode.
"Auto Mode" on page
24.
8
4
17.
6
7
OPERATION
Auto Mode